- Home
- ยป
- Our Products
- »
- Toxic Gas Leak Detector
Toxic Gas Leak Detector
Ethylene Gas Sensor Transmitter
Minimum Order Quantity: 1 Unit
Product Brochure
Power Supply | 16~30V DC |
Working Voltage | 24V DC +- 15% |
Working Humidity | Less than 95% R.H |
Combustible Gas | - 40 deg C ~ + 70 deg C |
Resolution | +- 3 ppm |
Ethylene (C2H4) toxic range sensor, analyser, detector, transmitter for industrial, commercial, pharmaceutical, chemical, Oil & gas, Cold room etc. Alvi Automation India Pvt Ltd. (Gas Alarm System India) offer Ethylene (C2H4) sensor transmitter / detector/ analyser from MSR Electronic, Germany with following features:
- Measuring range: 0-2000ppm
- Technology: Electro-chemical / galvanic , NDIR (analysis, toxic monitoring), Semiconductor (toxic monitoring)
- Output: 4-20mA, 0-10V, RS485 modbus, Lon, BacNET (Optional)
- Enclosure: IP44, IP54, IP65
- Certificate: UL 61010, UL 2075, ATEX EExd, ATEX EExn, CE
- Mounting: wall mountable, duct mountable
- Installation area: safe area, hazardous area, explosion-proof
Application areas:
Cold room, cold store, refrigeration, pharmceutical, chillar plant, cylinder store, gems processing, heat processing, furnace, steel, engine room, testing rooms, automobile, thermal power plant, defence, warship, cooling rooms, anniling plant, formulation plant, food processing, ammonia cracking unit, refinery, storage plants
Additional Information:
- Item Code: MA-3-2089-F-F
- Port of Dispatch: Air or Road
- Production Capacity: 50/ day
- Delivery Time: 1-2 days
Ethylene Oxide Gas Detector
Product Brochure
Gas Type | Toxic Gas |
Model Name/Number | MC2-X-E1199-X-X |
Usage/Application | Gas Detection |
Voltage | 24VDC |
Display Type | Digital |
Measurement Range | 0-10 ppm |
Color | Light Grey |
Size | (D x H) 24 x 22 mm |
Humidity | 15-90 umidity range |
Resolution | 0.01 |
Response Time | 140 sec. |
Sensor Life | 24 Months |
Accuracy | n.d. |
Warranty | 1 year |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Ethylene Oxide (ETO) Toxic gas.
The MC2-X-E1199-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical Ethylene Oxide (ETO) sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Item Code: MC2-X-E1199-X-X
- Production Capacity: 1000
- Delivery Time: 4-6 week
Flameproof Carbon Monoxide Detector
Product Brochure
Usage/Application | Industrial |
Model Name/Number | PX2 |
Sensor Type | CO Detector |
Display Type | Digital |
Measurement Range | 0-500ppm |
Brand | MSR Germany |
Color | Grey Steel |
Accuracy | 1% |
Weight | 1.5kg |
ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world class cutting edge Flameproof Carbon Monoxide (CO) Gas Detector and Monitor.
We are involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost effective appropriate solutions.
Description:
Flameproof Carbon Monoxide Detector is a highly robust, industrial grade, flameproof, or explosion-proof gas detector for Flameproof Carbon Monoxide Detector or CO PPM monitoring & Control Systems.
The detector is used for online, continuous monitoring of the CO toxic Gases in ambient air or duct or pipeline. It is ATEX, IECEx certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.
With Benefits:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- For zone 1 (and also suitable for zone 2) Type Ex dbwith flame proof enclosure
- For zone 2: Type Ex nA with flame-proof enclosure
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4-20 mA output
- Serial interface to the control centre
- Reverse polarity protection
- Overload protection
- LCD with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
Our customers come from various industries like oil/gas, chemical, manufacturing, petrochemical, pharmaceutical, building, mining, nuclear, steel, defense, power, water, wastewater, mining, cement, dairy, automobile, etc.
Additional Information:
- Production Capacity: 1000
- Delivery Time: 2-8 weeks
Hydrochloric Acid Gas Detector
Product Brochure
Gas Type | Toxic Gas |
Model Name/Number | MC2-X-E1186-X-X |
Usage/Application | Gas Detection |
Display Type | Digital |
Measurement Range | 0-20 ppm |
Color | Light Grey |
Size | (D x H) 24 x 22 mm |
Humidity | 15-90 umidity range |
Resolution | 0.01 |
Sensor Life | 24 Months |
Accuracy | n.d. |
Warranty | 1 year |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Hydrochloric Acid (HCl) Toxic gas.
The MC2-X-E1193-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical Hydrochloric Acid (HCl) sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Item Code: MC2-X-E1186-X-X
- Production Capacity: 1000
- Delivery Time: 4 to 6 weaks
Chlorine Gas Detector
Product Brochure
Minimum Order Quantity | 10 Unit |
Gas Type | Toxic Gas |
Brand | MSR |
Model Name/Number | MC2-X-E1193-X-X |
Sensor Type | Electrochemical |
Usage/Application | Gas Detection |
Voltage | 24VDC |
Weight | 150 gm |
Display Type | Digital |
Measurement Range | 4-20 mA or 2-10 V |
Color | Light Grey |
Size | (D x H) 24 x 22 mm |
Humidity | 15-90 umidity range |
Sensor Life | 24 Months |
Accuracy | n.d. |
Warranty | 1 year |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Chlorine (Cl2) Toxic gas.
The MC2-X-E1193-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical Chlorine (Cl2) sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Item Code: MC2-X-E1193-X-X
- Production Capacity: 1000
- Delivery Time: 4 TO 6 Weeks
Ethylene Gas Detector
Product Brochure
Gas Type | Toxic Gas |
Model Name/Number | MC2-X-E1189-X-X |
Usage/Application | Gas Detection |
Voltage | 24VDC |
Weight | 150 gm |
Display Type | Digital |
Measurement Range | 0-200 ppm |
Color | Light Grey |
Size | (D x H) 24 x 22 mm |
Humidity | 15-90 umidity range |
Resolution | 0.1 |
Response Time | 120 |
Sensor Life | 24 Months |
Accuracy | n.d. |
Warranty | 1 year |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Ethylene (C2H4) Toxic gas.
The MC2-X-E1125-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical Ethylene (C2H4) sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Item Code: MC2-X-E1189-X-X
- Production Capacity: 1000
- Delivery Time: 4-6 Week
Formaldehyde Gas Detector
Product Brochure
Model Name/Number | MC2-X-E1185-X-X |
Gas Type | Toxic Gas |
Display Type | Analog |
Measurement Range | 0-10 PPM |
Accuracy | 2 % |
Warranty | 1 year |
Humidity | 15-90 umidity range |
Resolution | .01 |
Response Time | 60 Sec |
Sensor Life | 36 Months |
Weight | 150 gm |
Color | Light Grey |
Voltage | 24VDC |
Usage/Application | Gas Detection |
Size | (D x H) 24 x 22 mm |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Formaldehyde (CH2O) Toxic gas.
The MC2-X-E1185-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical Formaldehyde (CH2O) sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Item Code: MC2-X-E1185-X-X
- Production Capacity: 1000
- Delivery Time: 4-6 Week
Ammonia Gas Detectors
Product Brochure
Minimum Order Quantity | 10 Piece |
Usage/Application | Industrial |
Display Type | Analog, Digital |
Model Name/Number | MC2-X-E1125-XX-X |
Weight | 150 g |
Measurement Range | 0-100, 0-300, 0-500, 0-1000 PPM |
Brand | MSR |
Color | Grey |
Resolution | 0.1 |
Gas Type | Ammonia |
Sensor Type | Electrochemical sensor |
Gard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Ammonia (NH3) Toxic gas.
The MC2-X-E1125-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical Ammonia (NH3) sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
Digital measurement value processing incl. temperature compensationData / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
High accuracy, selectivity, and reliability
Low zero point drift
Sensor life time: Refer the datasheet
SIL2 Compliant development process
Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
Reverse polarity protected, overload and short-circuit proof
Integrated heating down to -35C
Optional:Without housing
With housing Plastic: Type D, 94 x 65 x 57 mm
4-20 mA output signal
2-10 V output signal
With display for values and operation, 2x open collector for horn and warning lamp
Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe Gas Detectors and Alarm Systems
Additional Information:
- Item Code: MC2-X-E1125-XX-X-C
- Production Capacity: 1000
- Delivery Time: Ex-Stock or 4-6 weeks
Hydrogen Sulfide Gas Detector
Product Brochure
Minimum Order Quantity | 10 Unit |
Gas Type | Toxic Gas |
Model Name/Number | MC2-X-E1197-X-X |
Usage/Application | Gas Detection |
Voltage | 24VDC |
Weight | 150 gm |
Display Type | Digital |
Measurement Range | 0-100,0-200,0-500 PPM |
Color | Light Grey |
Size | (D x H) 24 x 22 mm |
Humidity | 15-90 umidity range |
Sensor Life | 24 Months |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Hydrogen Sulfide (H2S) Toxic gas.
The MC2-X-E1197-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical Hydrogen Sulfide (H2S) sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Item Code: MC2-X-E1197-X-X
- Production Capacity: 1000
- Delivery Time: Ex- Stock or 4-6 Weeks
Flameproof Nitrogen Dioxide (No2) Sensor Transmitter
Product Brochure
Minimum Order Quantity | 1 Unit |
Display Type | Analog, Digital |
Model Name/Number | Toxic Gas Detector |
Brand | MSR Germany |
Color | Grey Steel |
Measurement Range | 0-100 ppm |
Humidity | 95% |
Material | Electrochemiccal |
Power Source | 24VDC/230VAC |
ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world-class cutting edge Flameproof Nitrogen Dioxide (NO2) Gas Detector and Monitor.
We are involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.
Description:
Flameproof Nitrogen Dioxide Detector is a highly robust, industrial grade, flameproof, or explosion-proof gas detector for Flameproof NO2 or NO2 PPM monitoring & Control Systems.
The detector is used for online, continuous monitoring of the toxic Gases in ambient air or duct or pipeline. It is ATEX, IECEx certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.
With Benefits:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- For zone 1 (and also suitable for zone 2) Type Ex db with flame-proof enclosure
- For zone 2: Type Ex nA with flame-proof enclosure
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4 20 mA output
- Serial interface to the control centre
- Reverse polarity protection
- Overload protection
- LCD with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
Our customers come from various industries like oil/gas, chemical, manufacturing, petrochemical, pharmaceutical, building, mining, nuclear, steel, defense, power, water, wastewater, mining, cement, dairy, automobile, etc.
Additional Information:
- Production Capacity: 100
MSR Germany Flameproof Oxygen Sensor Transmitter
Product Brochure
Usage/Application | Industrial |
Display Type | Analog, Digital |
Brand | MSR Germany |
Model Name/Number | Oxygen Detetcor |
Measurement Range | 0-25% Vol |
Color | Grey Aluminium |
Material | Electrochemical |
Accuracy | 0.1 % |
ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world-class cutting edge Flameproof Oxygen Gas Detector Transmitter and Monitor.
We are involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.
Description:
Ex-proof Oxygen O2 Gas Detector Transmitter and Monitor is a highly robust, industrial grade, flameproof, or explosion-proof gas detector for Flameproof O2 gas or O2 detection in % Vol monitoring & Control Systems.
The detector is used for online, continuous monitoring of the O2 toxic Gases in ambient air or duct or pipeline. It is ATEX, IECEx certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.
With Benefits:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- For zone 1 (and also suitable for zone 2) Type Ex db with flame-proof enclosure
- For zone 2: Type Ex nA with flame-proof enclosure
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4 20 mA output
- Serial interface to the control centre
- Reverse polarity protection
- Overload protection
- LCD with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
Our customers come from various industries like oil/gas, chemical, manufacturing, petrochemical, pharmaceutical, building, mining, nuclear, steel, defense, power, water, wastewater, mining, cement, dairy, automobile, etc.
Additional Information:
- Production Capacity: 1000
- Delivery Time: 2-8 weeks
Oxygen(O2) and Carbon Dioxide(CO2) Gas Monitor in Makeshift Hospitals and Hospital Wards
Product Brochure
Display Type | Analog, Digital |
Brand | MSR Germany |
Model Name/Number | MC2-X-E1195-A3-0 |
Measurement Range | 0-25% Volume |
Material | Polycarbonate |
Accuracy | 0.1% |
Dimension | 94*87 |
Protection | IP65 |
Warranty | 12 months |
Weight | 200 gram |
Also in a poorly ventilated area, the nanodroplets caused due to sizzling by a corona infected patient may still be present in the atmospheric air level which might cause further spread of the virus, resulting in the widespread of a continuous chain of infection, hence control of enrichment level of oxygen level along with deficiency level of Oxygen level is very necessary for the health safety of patients and doctors.
With this said Carbon Dioxide(CO2) gas monitoring should not be neglected, especially in the crowded and poorly ventilated area where the increase of CO2 level is at higher risk causing the Symptoms like headache, tired, nausea, higher pulse rating, etc
We would love to assist you by providing our world-class standalone O2 + CO2 gas detection system with the most compact plug and play type sensor transmitter ready to be delivered by ALVI Group
Additional Information:
- Production Capacity: 1000 nos.
- Delivery Time: 1 weeks
- Packaging Details: Standard
Msr Germany Hydrogen Cyanide (Hcn) Detector
Product Brochure
Minimum Order Quantity | 1 Piece |
Gas Type | Toxic Gas Detector |
Brand | MSR Germany |
Model Name/Number | PX2 HCN |
Sensor Type | Electrochemical |
Usage/Application | Gas Detection |
Voltage | 24Vdc |
Weight | 1.5kg |
Display Type | Digital |
Measurement Range | 0-100ppm |
ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world-class cutting edge Flameproof Hydrogen Cyanide (HCN) Gas Detector Transmitter and Monitor.
We are involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.
Description:
Ex-proof Hydrogen Cyanide (HCN) Gas Detector Transmitter and Monitor is a highly robust, industrial grade, flameproof, or explosion-proof gas detector for Flameproof HCN gas or HCN PPM monitoring & Control Systems.
The detector is used for online, continuous monitoring of the HCN toxic Gases in ambient air or duct or pipeline. It is ATEX, IECEx certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.
With Benefits:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- For zone 1 (and also suitable for zone 2) Type Ex db with flame-proof enclosure
- For zone 2: Type Ex nA with flame-proof enclosure
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4 20 mA output
- Serial interface to the control centre
- Reverse polarity protection
- Overload protection
- LCD with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
Our customers come from various industries like oil/gas, chemical, manufacturing, petrochemical, pharmaceutical, building, mining, nuclear, steel, defense, power, water, wastewater, mining, cement, dairy, automobile, etc.
Additional Information:
- Production Capacity: 100
- Delivery Time: 2-8 weeks
Freon R123 Gas Sensor
Product Brochure
Measuring Range | 0-300 ppm |
Resolution | +- 3 ppm |
Sensor Coverage Area | 700 m2 to 750 m2 |
Power Supply | 18 - 28 VDC |
Working Temperature | -10deg C to +50deg C |
Model No | MSR - MA-4-2064 |
Nitrogen Dioxide Gas Detector
Product Brochure
Gas Type | Toxic Gas |
Model Name/Number | MC2-X-E1130-X-X |
Usage/Application | Gas Detection |
Voltage | 24VDC |
Weight | 150 gm |
Display Type | Digital |
Measurement Range | 0-10,0-20PPM,0-100 %VOL. |
Color | Light Grey |
Size | (D x H) 24 x 22 mm |
Humidity | 15-90 umidity range |
Response Time | 25 SEC. |
Sensor Life | 24 Months |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Nitrogen Oxide (NO2) Toxic gas.
The MC2-X-E1130-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical Nitrogen Oxide (NO2) sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Item Code: MC2-X-E1130-X-X
- Production Capacity: 1000
- Delivery Time: Ex Stock or 4 to 6 weeks
Ex-Proof Hydrogen Sulphide (H2s) Gas Detector Transmitter
Product Brochure
Minimum Order Quantity | 1 Unit |
Sensor Type | Electrochemical |
Brand | MSR Germany |
Color | Grey Aluminium |
Gas Type | H2S Hydrogen Sulphide Detector |
Display Type | Analog, Digital |
Material | Gas detector |
Measurement Range | 0-500ppm |
Alarms | 2 |
ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world-class cutting edge Flameproof Hydrogen Sulphide (H2S) Gas Detector Transmitter and Monitor.
We are involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.
Description:
Ex-proof Hydrogen Sulphide (H2S) Gas Detector Transmitter and Monitor is a highly robust, industrial grade, flameproof, or explosion-proof gas detector for Flameproof H2S gas or H2S PPM monitoring & Control Systems.
The detector is used for online, continuous monitoring of the H2S toxic Gases in ambient air or duct or pipeline. It is ATEX, IECEx certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.
With Benefits:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- For zone 1 (and also suitable for zone 2) Type Ex db with flame-proof enclosure
- For zone 2: Type Ex nA with flame-proof enclosure
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4 20 mA output
- Serial interface to the control centre
- Reverse polarity protection
- Overload protection
- LCD with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
Our customers come from various industries like oil/gas, chemical, manufacturing, petrochemical, pharmaceutical, building, mining, nuclear, steel, defense, power, water, wastewater, mining, cement, dairy, automobile, etc.
Additional Information:
- Production Capacity: 100
Refrigerant R22 Gas Sensor Transmitter
Product Brochure
μGard®2 R123 Freon and Refrigerants Gas Transmitter MC2-X-S2064-01-A -X-X GasAlarm
μGard®2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect R123 refrigerant gas.
The MC2-X-S2064-01-A -X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Semi-Conductor R123 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor lifetime: > 5 years / normal environment
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault, etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Plug and play type concept for field calibration, laboratory calibration and site calibration (where the housing of the gas sensor remains on to the wall with cable wiring and later sensor cell transmitter cartridge can be plugin after calibration)
- Smart digital type calibration facility with an indication of the life of the sensor cell.
- Simplified maintenance via the exchange of pre-calibrated sensor cartridges or easy on site-calibration.
- Tough, rugged, glass-fibre reinforced, Impact resistant, fully gasketed
Polycarbonate IP 65 enclosure. - IP65 protected housing, with the provision of dust and moisture protection with
Hydrophobic filter arrangement. - Monitoring of R123 can be achieved with our optional MSR centralized Gas control and monitoring system to meet the global ventilation standards like:
o EN 378
o EN 14624
o EN 45544-1
o EN 61508-1-3
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts to info
Hydrogen Cyanide Gas Detector
Product Brochure
Gas Type | Toxic Gas |
Brand | MSR |
Model Name/Number | MC2-X-E1183-X-X |
Sensor Type | Electrochemical |
Usage/Application | Gas Detection |
Voltage | 24VDC |
Weight | 150 gm |
Display Type | Digital |
Measurement Range | 0-50,0-100 ppm |
Color | Light Grey |
Size | (D x H) 24 x 22 mm |
Humidity | 15-90 umidity range |
Sensor Life | 24 Months |
Accuracy | 5 % |
Warranty | 1 year |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Hydrogen Cyanide (HCN) Toxic gas.
The MC2-X-E1125-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical Hydrogen Cyanide (HCN) sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe - Gas Detectors and Alarm Systems
Additional Information:
- Item Code: MC2-X-E1183-X-X
- Production Capacity: 1000
- Delivery Time: 4 to 6 week
Carbone Monoxide Gas Detector
Product Brochure
Gas Type | Toxic Gas |
Model Name/Number | MC2-X-E1110-X-X |
Usage/Application | Gas Detection |
Voltage | 24VDC |
Display Type | Digital |
Measurement Range | 0-100,0-150,0-250,0-300,0-500 PPM |
Color | Light Grey |
Size | (D x H) 24 x 22 mm |
Material | Polycarbonate |
Humidity | 10-95 % r.f. |
Resolution | 0.1 ppm |
Response Time | 10 sec. |
Sensor Life | 72 Months |
Accuracy | +- 2% |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Carbone Mono oxide (CO) Toxic gas.
The MC2-X-E1110-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical Carbone Mono oxide (CO) sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
\Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Item Code: MC2-X-E1110-X-X
- Production Capacity: 1000
- Delivery Time: EX-Stocks or 4 to 6 Weeks
Ozone Gas Detector
Product Brochure
Gas Type | Toxic Gas |
Model Name/Number | MC2-X-E1190-X-X |
Usage/Application | Gas Detection |
Voltage | 24VDC |
Display Type | Digital |
Measurement Range | 0-5,0-10 PPM |
Color | Light Grey |
Size | (D x H) 24 x 22 mm |
Material | Polycarbonate |
Humidity | 15-90 % umidity range |
Sensor Life | 24 Months |
Accuracy | n.d. |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Ozone (O3) Toxic gas.
The MC2-X-E1190-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical Ozone (O3) sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Item Code: MC2-X-E1190-X-X
- Production Capacity: 1000
- Delivery Time: EX Stocks or 4 to 6 Weeks
Oxygen Gas Detector
Product Brochure
Display Type | Digital |
Gas Type | Toxic Gas |
Humidity | 5-95 % |
Measurement Range | 0-25 PPM |
Response Time | 15 sec. |
Color | Light Grey |
Voltage | 24VDC |
Weight | 150 gm |
Model Name/Number | MC2-X-E1195-A-X |
Size | (D x H) 24 x 22 mm |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Oxygen (O2) Toxic gas.
The MC2-X-E1195-A-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical Oxygen (O2) sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Item Code: MC2-X-E1195-A-X
- Production Capacity: 1000
- Delivery Time: 4-6 Weeks
Acetone Gas Detector
Product Brochure
Display Type | Digital, Analog |
Brand | MSR |
Model Name/Number | MC2-X-P3485-A-X-X |
Weight | 150 g |
Power | 24 VDC |
Material | Polycarbonate or SS |
Accuracy | 1% LEL |
Measurement Range | 0-100% LEL or % Vol |
Color | Grey |
Humidity Range | 5-95 % RH not condensing |
Mounting Type | Depending o Gas Density |
Gard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self control for the continuous monitoring of the ambient air to detect Acetone (C3H6O) Combustible/Flammable gas.
The MC2-XP3485 X X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catalytic Pellistor Bead (C3H6O) sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4 20 mA (or 2 10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
Digital measurement value processing incl. temperature compensationData / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
Low zero point drift
Sensor life time: Refer the datasheet
SIL2 Compliant development process
Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
4 20 mA (or 2 10V) analog output with selectable signal output for special mode, fault etc.
Reverse polarity protected, overload and short-circuit proof
Integrated heating down to 35COptional:Without housing
With housing Plastic: Type D, 94 x 65 x 57 mm
4 20 mA output signal
2 10 V output signal
With display for values and operation, 2x open collector for horn and warning lamp
Conformity to:
o EN 50271
o EN 50545:2017
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2 10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Should you have any questions or concerns regarding this matter, please
Be sure, Be safe Gas Detectors and Alarm Systems
Additional Information:
- Item Code: MC2-X-P3485-A-X-X
- Production Capacity: 1000
- Delivery Time: Ex-Stock or 4-6 Weeks
Sulfur Dioxide Gas Detector
Product Brochure
Gas Type | Toxic Gas |
Usage/Application | Gas Detection |
Voltage | 24VDC |
Weight | 150 gm |
Display Type | Digital |
Measurement Range | 0-50 PPM |
Color | Light Grey |
Size | (D x H) 24 x 22 mm |
Humidity | 15-90 umidity range |
Resolution | 0.01 |
Response Time | 30 sec. |
Sensor Life | 24 Months |
Warranty | 1 year |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Sulfur Dioxide (SO2) Toxic gas.
The MC2-X-E1196-B-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical Sulfur Dioxide (SO2) sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Item Code: MC2-X-E1196-B-X
- Production Capacity: 1000
- Delivery Time: EX-Stock or 4-6 Weeks