Call 08048989985 86% Response Rate

Send Email

Flammable Combustible Gas Leak Detector

Providing you the best range of ammonia gas sensor transmitter, toluene gas detector and monitor (c7h8), msr germany n-heptane gas sensor, msr germany iecex, atex, sil2 toluene gas sensor, msr germany iecex, atex, sil2 propane gas sensor and msr germany iecex, atex, sil2 cyclopentane gas sensor with effective & timely delivery.

Ammonia Gas Sensor Transmitter

Ammonia Gas Sensor Transmitter
  • Ammonia Gas Sensor Transmitter
  • Ammonia Gas Sensor Transmitter
  • Ammonia Gas Sensor Transmitter
  • Ammonia Gas Sensor Transmitter
  • Ammonia Gas Sensor Transmitter
  • Ammonia Gas Sensor Transmitter
  • Ammonia Gas Sensor Transmitter
Get Best Quote
Product Price: Rs 40,000 / PieceGet Best Price

Product Brochure

Product Details:
Gas TypeCombustible Gas
Operating Temperature-30 DegreeC to +60 DegreeC (-22 DegreeF to 140 DegreeF)
BrandMSR Germany
Operating Humidity5-95 % RH not condensing
Expected Operating LifeNA
Model Name/NumberMC2-X-P3408-A-X-X
Sensor TypeCatalytic Pellistor
Measuring Range0-100%LEL
Usage/ApplicationIndustrial
Voltage24VDC
Weight200gms
Display TypeOptional

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect NH3 Flammable/Combustible gas.

The MC2-X-P3408-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catalytic Pellistor Bead Sensor NH3 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Item Code: MC2-X-P3408-A-X-X
  • Production Capacity: 1000
  • Delivery Time: Ex-Stock or 4-6 Weeks
Yes! I am InterestedRequest A Callback

Toluene Gas Detector and Monitor (C7H8)

Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Display TypeAnalog
BrandMSR Electronics
Model Name/NumberPX2-X-XXXX-X-X
Weight1.5 Kg
Power24VDC
MaterialAluminium die-casting or SS
Measurement Range% LEL
Accuracy+/- 1% LEL
Battery LifeNA
Status IndicationYes
Voltage24VDC
Warranty1 year
Signal Output4-20mA
ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world class cutting edge Toluene Gas Detector and Monitor (C7H8)

We are is involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.

FEATURES:

• ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection• Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay• For zone 1 (and also suitable for zone 2) Type “Ex db” with flame-proof enclosure• For zone 2: Type “Ex nA” with flame-proof enclosure• Continuous monitoring• Microprocessor with 12-bit converter resolution• Self-monitoring system• Easy calibration• Calibration service by exchanging the sensor head• Proportional 4–20 mA output• Serial interface to the control centre• Reverse polarity protection• Overload protection• LCD with status LEDs (optional)• Alarm and fault signal relay (optional)

Application:

• Coal mines, underground mines• Oil & gas, refinery• Fertilizer industry• Landfill gases• Sewage treatment plants (STP), effluent treatment facility• Cryogenic application• Chemical, petrochemical industry• Food processing industry• Furnace, burner application• Gas reticulation system

 
#TolueneDetector #Toluene Monitor #C7H8Detector #C7H8Monitor#FlammableLiquid#ExplosiveGas#FlammableGas#SolventMonitoring#ATEX#SIL2#IECEx #PESO #CCOE #DGMS #CMRI#Intrinsicallysafe#ExplosionProof#FlameProof#ZONE1#ZONE2#IECExCertified#ATEXCertified#SIL2Certified#HARTProtocol#ATEXGasDetector#ExplosionProof#ExplosiveGas#FlameproofGasDetector#FlameproofGasSensor#FlammableGas#Gasdetector#Gassensor#LEL#VOL#Detector#SIL2#Zone1#Zone2#Accessories #Adapter#Calibration #CalibrationGas#CellarAlarm #DigitalBusSensors #EnvironmentalMonitoring #FlameDetector#Fumigation #FumigationProducts#GasAlarm #GasControllers #GasDetectorTubes #GasTransmitters#GasSensorTransmitters#HandPumpsAccessories#HandTool#HazardousAre #IndoorAirQuality #MAPAnalysers #PolyGard2 #PolyXeta2 #Standalone #μGard2MC2Series#JunctionBO #JunctionBOXCopperFree#JunctionBoxMarineGrade#MarineGradeEnlosure#StainlessSteelEclocsure#StainlessSteelHousing#12BitConverterResolution#ExnA#Exdb#ElectricalExprotected#MetrologicalTesting#RS485#HART#Relay#LED#LCD#Continuousmonitoring#SelfMonitoringSystem#Easycalibration#Calibrationservice#exchanging#sensorhead#PlugPlay#4to20mAoutput#SerialInterface#ReversePolarityProtection#OverloadProtection#LCDDisplay#StatusLEDs #AlarmRelay#FaultSignalRelay
Yes! I am InterestedRequest A Callback

MSR Germany n-Heptane Gas Sensor

MSR Germany n-Heptane Gas Sensor
  • MSR Germany n-Heptane Gas Sensor
  • MSR Germany n-Heptane Gas Sensor
  • MSR Germany n-Heptane Gas Sensor
  • MSR Germany n-Heptane Gas Sensor
  • MSR Germany n-Heptane Gas Sensor
  • MSR Germany n-Heptane Gas Sensor
  • MSR Germany n-Heptane Gas Sensor
  • MSR Germany n-Heptane Gas Sensor
  • MSR Germany n-Heptane Gas Sensor
  • MSR Germany n-Heptane Gas Sensor
  • MSR Germany n-Heptane Gas Sensor
  • MSR Germany n-Heptane Gas Sensor
  • MSR Germany n-Heptane Gas Sensor
  • MSR Germany n-Heptane Gas Sensor
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Operating Temperature-20-50
Operating Humidity95%
Expected Operating Life3-5 years
Measuring Range0-100% LEL
Response Time10 second
Display TypeDigital, Analog
Model Name/Numbern-Heptane Gas Sensor
Weight1.2 Kg
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Production Capacity: 100
  • Delivery Time: 2-8 weeks
Yes! I am InterestedRequest A Callback

MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor

MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Operating Temperature-20-50
Operating Humidity95%
Expected Operating Life3-5 years
Measuring Range0-100% LEL
Response Time10 second
Display TypeAnalog, Digital
BrandMSR Germany
Weight1.2 Kg
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 2-8 weeks
Yes! I am InterestedRequest A Callback

MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor

MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Display TypeDigital, Analog
BrandMSR Germany
Model Name/NumberPropane Gas Leak Detection
Weight1.2 Kg
Power24VDC
MaterialAluminium di caste
Measurement Range0-100% LEL
Accuracy1%
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Delivery Time: 2-8 weeks
Yes! I am InterestedRequest A Callback

MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor

MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Display TypeDigital, Analog
BrandMSR Germany
Model Name/NumberPropane Gas Leak Detection
Weight1.2 Kg
Power24VDC
MaterialAluminium di caste
Measurement Range0-5000 ppm
Accuracy1%
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Delivery Time: 2-8 weeks
Yes! I am InterestedRequest A Callback

MSR Germany IECEx, ATEX, SIL2 Cyclopentane Gas Sensor

MSR Germany IECEx, ATEX, SIL2 Cyclopentane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Cyclopentane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Cyclopentane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Cyclopentane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Cyclopentane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Cyclopentane Gas Sensor
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Operating Temperature-20-50
Operating Humidity95%
Expected Operating Life3-5 years
Measuring Range0-100% LEL
Response Time10 second
Display TypeAnalog, Digital
Model Name/NumberCyclopentane Gas Sensor
Weight1.2 Kg
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Delivery Time: 2-8 weeks
Yes! I am InterestedRequest A Callback

MSR Germany IECEx, ATEX, SIL2 Octane Gas Sensor

MSR Germany IECEx, ATEX, SIL2 Octane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Octane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Octane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Octane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Octane Gas Sensor
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Display TypeAnalog, Digital
BrandMSR Germany
Weight1.2 Kg
Model Name/NumberOctane Gas Sensor
Power24VDC
MaterialAluminium di cast
Accuracy1%
Measurement Range0-100% LEL
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Delivery Time: 2-8 weeks
Yes! I am InterestedRequest A Callback

MSR Germany Methyl Ethyl Ketone Gas Detector

MSR Germany Methyl Ethyl Ketone Gas Detector
  • MSR Germany Methyl Ethyl Ketone Gas Detector
  • MSR Germany Methyl Ethyl Ketone Gas Detector
  • MSR Germany Methyl Ethyl Ketone Gas Detector
  • MSR Germany Methyl Ethyl Ketone Gas Detector
  • MSR Germany Methyl Ethyl Ketone Gas Detector
  • MSR Germany Methyl Ethyl Ketone Gas Detector
  • MSR Germany Methyl Ethyl Ketone Gas Detector
  • MSR Germany Methyl Ethyl Ketone Gas Detector
  • MSR Germany Methyl Ethyl Ketone Gas Detector
  • MSR Germany Methyl Ethyl Ketone Gas Detector
  • MSR Germany Methyl Ethyl Ketone Gas Detector
Get Best Quote
Product Price: Rs 50,000 / PieceGet Best Price

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
BrandMSR Germany
Model Name/NumberMC2-X-P3458-A-X-X
Usage/ApplicationIndustrial
ColorGrey
Measurement Range0-100% LEL
I Deal InNew Only
Signal OutputAnalog 4-20mA

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C4H8O Combustible gas.

The MC2-X-P3458-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C4H8O sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 



Additional Information:

  • Production Capacity: 1000
Yes! I am InterestedRequest A Callback

MSR Germany Ex-Proof Nonane Sensor Transmitter

MSR Germany Ex-Proof Nonane Sensor Transmitter
  • MSR Germany Ex-Proof Nonane Sensor Transmitter
  • MSR Germany Ex-Proof Nonane Sensor Transmitter
  • MSR Germany Ex-Proof Nonane Sensor Transmitter
  • MSR Germany Ex-Proof Nonane Sensor Transmitter
  • MSR Germany Ex-Proof Nonane Sensor Transmitter
Get Best Quote
Get Latest Price

Product Details:
Minimum Order Quantity1 Piece
Display TypeAnalog, Digital
Output Signal4-20mA
Model Name/NumberNonane Gas Detector
Weight1.2 Kg
BrandMSR Germany

ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world-class cutting edge Flameproof Nonane Gas Detector Transmitter and Monitor.

We are  involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.

Description:

Ex-proof Nonane (C9H20) Gas Detector Transmitter and Monitor is a highly robust, industrial grade, flameproof, or explosion-proof gas detector for Flameproof C9H20 gas or Nonane detection in % LEL monitoring & Control Systems.

The detector is used for online, continuous monitoring of the Nonane Combustible Gases in ambient air or duct or pipeline. It is ATEX, IECEx certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.

With Benefits:

  • ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  • Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
  • For zone 1 (and also suitable for zone 2) Type Ex db with flame-proof enclosure
  • For zone 2: Type Ex nA with flame-proof enclosure
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  • Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4 20 mA output
  • Serial interface to the control centre
  • Reverse polarity protection
  • Overload protection
  • LCD with status LEDs (optional)
  • Alarm and fault signal relay (optional)

 

Our Industries:
Our customers come from various industries like oil/gas, chemical, manufacturing, petrochemical, pharmaceutical, building, mining, nuclear, steel, defense, power, water, wastewater, mining, cement, dairy, automobile, etc. 



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 2-8weeks
Yes! I am InterestedRequest A Callback

Flameproof Petrol Diesel Vapours Sensor Transmitter

Flameproof Petrol Diesel Vapours Sensor Transmitter
  • Flameproof Petrol Diesel Vapours Sensor Transmitter
  • Flameproof Petrol Diesel Vapours Sensor Transmitter
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Display TypeDigital, Analog
Model Name/NumberPetrol Diesel Detector
Weight1.2 Kg
BrandMSR Germany
Measurement Range0-100% LEL
Power24VDC
MaterialAluminium
Accuracy1%

ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world-class cutting edge Flameproof Petrol Vapours Gas Detector Transmitter and Monitor.

We are  involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.

Description:

Ex-proof Petrol Vapours Sensor Transmitter and Monitor is a highly robust, industrial grade, flameproof, or explosion-proof gas detector for Flammable Petrol/Diesel Vapours detection in % LEL monitoring & Control Systems.

The detector is used for online, continuous monitoring of the  Flammable Gases in ambient air or duct or pipeline. It is ATEX, IECEx certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.

With Benefits:

  • ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  • Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
  • For zone 1 (and also suitable for zone 2) Type Ex db with flame-proof enclosure
  • For zone 2: Type Ex nA with flame-proof enclosure
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  • Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4 20 mA output
  • Serial interface to the control centre
  • Reverse polarity protection
  • Overload protection
  • LCD with status LEDs (optional)
  • Alarm and fault signal relay (optional)

 

Our Industries:
Our customers come from various industries like oil/gas, chemical, manufacturing, petrochemical, pharmaceutical, building, mining, nuclear, steel, defense, power, water, wastewater, mining, cement, dairy, automobile, etc. 



Additional Information:

  • Production Capacity: 100
  • Delivery Time: 2 to 8 weeks
Yes! I am InterestedRequest A Callback

MSR Germany IECEx, ATEX, SIL2 Methyl Acetate Gas Sensor

MSR Germany IECEx, ATEX, SIL2 Methyl Acetate Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Methyl Acetate Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Methyl Acetate Gas Sensor
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Display TypeDigital, Analog
BrandMSR Germany
Gas TypeCombustible Gas
Model Name/NumberMethyl Acetate Gas Sensor
Power24VDC
Weight1.2 kg
Sensor TypeLPG
Voltage24vdc
Usage/ApplicationGas Detection
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Delivery Time: 2-8 weeks
Yes! I am InterestedRequest A Callback

MSR Germany IECEx, ATEX, SIL2 Hydrogen Gas Detector

MSR Germany IECEx, ATEX, SIL2 Hydrogen Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Hydrogen Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Hydrogen Gas Detector
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Display TypeDigital, Analog
Measurement Range0-100 % LEL
BrandMSR Germany
Model Name/NumberFlamepoof Hydrogen Gas Detector
Power Source24vdc
Driven TypeContinuous Detection
ColorGrey Aluminium
MaterialAluminium Di cast
Voltage24vdc
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4 20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
  • PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4 20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, 



Additional Information:

  • Delivery Time: 2-8 weeks
Yes! I am InterestedRequest A Callback

Hydrogen Gas Sensor

Hydrogen Gas Sensor
Get Best Quote
Product Price: Rs 38,000 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Details:
Gas Detection Range0-100 ppm
High sensitivity to1%
Made InGermany

We have Refrigerant Gas Detector in our product range which is highly accurate & fast responsive at the low-cost price having a long life benefit

As we know that Refrigerants gas are heavier than air. They tend to remain stagnant and progressively replace oxygen. For optimal efficiency of your refrigerant leak detection system, refrigerant sensors should be placed under the cooling unit and linked to a gas detection display control unit. In case of leakage, the controller unit will shut down the power supply of the cooling installation.

PolyGard®2 sensors are used for leakage detection in refrigeration systems. Refrigerants are highly toxic and usually very harmful to the environment. An undesired leakage of the refrigerant has to be strictly avoided. The gas alarm systems of MSR-Electronic reliably detect any gas leaks.

First and foremost you protect human life and the refrigeration system is monitored.

All products comply with and even exceed the new European standard EN 378.

  • Please watch a simple demo of our Gas leak Control and Monitoring System – click here
  • All these sensors are manufactured in Germany hence quality and reliability are assured.


Additional Information:

  • Item Code: MC2-H2
  • Production Capacity: 1000
  • Delivery Time: ready Stocks
Yes! I am InterestedRequest A Callback

IECEx, ATEX, SIL2 Butadiene Gas Detector

IECEx, ATEX, SIL2 Butadiene Gas Detector
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Display TypeAnalog, Digital
BrandMSR Germany
Model Name/NumberButadiene Sensor
Weight1.2 Kg
Power24VDC
MaterialAluminium di cate
Measurement Range0-100%
Accuracy1%
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Production Capacity: 100
  • Delivery Time: 2-8 weeks
Yes! I am InterestedRequest A Callback

MSR Germany Cyclohexane Gas Detector

MSR Germany Cyclohexane Gas Detector
  • MSR Germany Cyclohexane Gas Detector
  • MSR Germany Cyclohexane Gas Detector
  • MSR Germany Cyclohexane Gas Detector
  • MSR Germany Cyclohexane Gas Detector
  • MSR Germany Cyclohexane Gas Detector
  • MSR Germany Cyclohexane Gas Detector
  • MSR Germany Cyclohexane Gas Detector
  • MSR Germany Cyclohexane Gas Detector
  • MSR Germany Cyclohexane Gas Detector
  • MSR Germany Cyclohexane Gas Detector
Get Best Quote
Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec.
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeOptional, Digital
BrandMSR Germany
Model Name/NumberMC2-X-P3415-A-X-X
Weight200gms
Power24VDC
Usage/ApplicationIndustrial
MaterialPoycarbonate Enclosure
Operating Voltage24VDC
Accuracy1% LEL
Measurement Range0-100%LEL
ColorGrey
Digital OutputNO
Humidity Range5-95 % RH not condensing
Mounting TypeDepending On Gas Type
Voltage24VDC
Signal OutputAnalog 4-20mA
Sensor TypeCatalytic Pellistor
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C6H12 Combustible gas.

The MC2-X-P3415-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Cataylitic Pellistor C6H12  sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:

      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: Ex Stock or 4-6 Weeks
Yes! I am InterestedRequest A Callback

MSR Germany Butyl Acetate Gas Detector

MSR Germany Butyl Acetate Gas Detector
  • MSR Germany Butyl Acetate Gas Detector
  • MSR Germany Butyl Acetate Gas Detector
  • MSR Germany Butyl Acetate Gas Detector
  • MSR Germany Butyl Acetate Gas Detector
  • MSR Germany Butyl Acetate Gas Detector
  • MSR Germany Butyl Acetate Gas Detector
  • MSR Germany Butyl Acetate Gas Detector
  • MSR Germany Butyl Acetate Gas Detector
  • MSR Germany Butyl Acetate Gas Detector
  • MSR Germany Butyl Acetate Gas Detector
Get Best Quote
Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity+5 DegreeC to +30 DegreeC
Measuring Range0-100% LEL
Response Time< 15 sec.
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital, Optional
BrandMSR Germany
Model Name/NumberMC2-X-P3448-A-X-X
Weight200gms
Power24VDC
Usage/ApplicationIndustrial
MaterialPolycarbonate Enclosure
Operating Voltage24VDC
Measurement Range0-100%LEL
Accuracy1% LEL
ColorGrey
Shell MaterialPolycarbonate
Signal OutputAnalog 4-20mA
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C6H12O2 Combustible gas.

The MC2-X-E1110-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catalytic Pellistor C6H12O2 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Item Code: MC2-X-P3448-A-X-X
  • Production Capacity: 1000
  • Delivery Time: Ex-Stock or 4-6 weeks
Yes! I am InterestedRequest A Callback

MSR Germany Cyclopentane Gas Detector

MSR Germany Cyclopentane Gas Detector
  • MSR Germany Cyclopentane Gas Detector
  • MSR Germany Cyclopentane Gas Detector
  • MSR Germany Cyclopentane Gas Detector
  • MSR Germany Cyclopentane Gas Detector
  • MSR Germany Cyclopentane Gas Detector
  • MSR Germany Cyclopentane Gas Detector
  • MSR Germany Cyclopentane Gas Detector
  • MSR Germany Cyclopentane Gas Detector
  • MSR Germany Cyclopentane Gas Detector
  • MSR Germany Cyclopentane Gas Detector
Get Best Quote
Product Price: Rs 1 / PieceGet Best Price

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec.
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital, Optional
Model Name/NumberMC2-X-X-P3472-A-X
Weight200gms
Measurement Range0-100% LEL
Power24VDC
Usage/ApplicationIndustrial
Operating Voltage24VDC
BrandMSR Germany
ColorGrey
Accuracy1% LEL
Humidity Range5-95 % RH not condensing
MaterialPolycarbonate
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C5H10 Combustible gas.

The MC2-X-P3472-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catalytic Pellisytor C5H10 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
Yes! I am InterestedRequest A Callback

MSR Germany Ethane Gas Detector

MSR Germany Ethane Gas Detector
  • MSR Germany Ethane Gas Detector
  • MSR Germany Ethane Gas Detector
  • MSR Germany Ethane Gas Detector
  • MSR Germany Ethane Gas Detector
  • MSR Germany Ethane Gas Detector
  • MSR Germany Ethane Gas Detector
Get Best Quote
Product Price: Rs 1 / PieceGet Best Price

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec.
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeOptional, Digital
Model Name/NumberMC2-X-P3420-A-X-X
Weight200gms
BrandMSR Germany
Measurement Range0-100% LEL
Power24VDC
Usage/ApplicationIndustrial
Operating Voltage24VDC
MaterialPolycarbonate Enclosure
Accuracy1% LEL
ColorGrey
Humidity Range5-95 % RH not condensing
Mounting TypeDepending on Gas Type
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C2H6 Combustible gas.

The MC2-X-P3420-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C2H6 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
Yes! I am InterestedRequest A Callback

MSR Germany Ethyl Alcohol Gas Detector

MSR Germany Ethyl Alcohol Gas Detector
  • MSR Germany Ethyl Alcohol Gas Detector
  • MSR Germany Ethyl Alcohol Gas Detector
  • MSR Germany Ethyl Alcohol Gas Detector
  • MSR Germany Ethyl Alcohol Gas Detector
  • MSR Germany Ethyl Alcohol Gas Detector
  • MSR Germany Ethyl Alcohol Gas Detector
  • MSR Germany Ethyl Alcohol Gas Detector
  • MSR Germany Ethyl Alcohol Gas Detector
  • MSR Germany Ethyl Alcohol Gas Detector
  • MSR Germany Ethyl Alcohol Gas Detector
Get Best Quote
Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Product Brochure

Product Details:
Gas TypeCombustible Gas
Usage/ApplicationIndustrial
Display TypeDigital
BrandMSR Germany
Model Name/NumberMC2-X-P3425-A-X-X
Weight200gms
Power24VDC
MaterialPolycarbonate Enclosure
Humidity5-95 % RH not condensing
Response Time< 15 sec. (CH4)
Measurement Range0-100% LEL
Accuracy1% LEL
Humidity Range5-95 % RH not condensing
Mounting TypeDepending on Gas
Voltage24VDC
Gases MeasuredEthyl alcohol,C2H5OH
I Deal InNew Only
Sensing ElementCatalytic Pellistor
Place Of OriginGermany

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C2H5OH Combustible gas.

The MC2-X-P3425-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C2H5OH sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe - Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: Ex stock or 4-6 Weeks
Yes! I am InterestedRequest A Callback

MSR Germany Ethylene Gas Detector

MSR Germany Ethylene Gas Detector
  • MSR Germany Ethylene Gas Detector
  • MSR Germany Ethylene Gas Detector
  • MSR Germany Ethylene Gas Detector
  • MSR Germany Ethylene Gas Detector
  • MSR Germany Ethylene Gas Detector
  • MSR Germany Ethylene Gas Detector
  • MSR Germany Ethylene Gas Detector
  • MSR Germany Ethylene Gas Detector
Get Best Quote
Product Price: Rs 35,000 / PieceGet Best Price

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-X-P3410-A-X
Weight200gms
BrandMSR Germany

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C2H4 Combustible gas.

The MC2-X-P3410-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C2H4 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
Yes! I am InterestedRequest A Callback

Msr Germany Methane Gas Detector

Msr Germany Methane Gas Detector
  • Msr Germany Methane Gas Detector
  • Msr Germany Methane Gas Detector
  • Msr Germany Methane Gas Detector
  • Msr Germany Methane Gas Detector
  • Msr Germany Methane Gas Detector
  • Msr Germany Methane Gas Detector
  • Msr Germany Methane Gas Detector
  • Msr Germany Methane Gas Detector
  • Msr Germany Methane Gas Detector
  • Msr Germany Methane Gas Detector
Get Best Quote
Product Price: Rs 40,000 / PieceGet Best Price

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-P3400-A-X-X
Weight200gms
Power24VDC
Usage/ApplicationIndustrial
BrandMSR Germany
ColorGrey
I Deal InNew Only
Sensor TypeCatalytic Pellistor

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Methane Combustible gas.

The MC2-X-P3400-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the CH4 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 



Additional Information:

  • Production Capacity: 1000
Yes! I am InterestedRequest A Callback

MSR Germany Methanol Gas Detector

MSR Germany Methanol Gas Detector
  • MSR Germany Methanol Gas Detector
  • MSR Germany Methanol Gas Detector
  • MSR Germany Methanol Gas Detector
  • MSR Germany Methanol Gas Detector
  • MSR Germany Methanol Gas Detector
  • MSR Germany Methanol Gas Detector
  • MSR Germany Methanol Gas Detector
  • MSR Germany Methanol Gas Detector
  • MSR Germany Methanol Gas Detector
  • MSR Germany Methanol Gas Detector
  • MSR Germany Methanol Gas Detector
  • MSR Germany Methanol Gas Detector
  • MSR Germany Methanol Gas Detector
  • MSR Germany Methanol Gas Detector
Get Best Quote
Product Price: Rs 1 / PieceGet Best Price

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-P3450-A-X-X
Weight200gms
Measurement Range0-100% LEL
Power24VDC
Usage/ApplicationIndustrial
BrandMSR Germany
ColorGrey
Mounting TypeDepending on Gas Type
I Deal InNew Only
Sensor TypeCatalytic Pellistor

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect CH3OH Combustible gas.

The MC2-X-P3450-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the CH3OH module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 



Additional Information:

  • Production Capacity: 1000
Yes! I am InterestedRequest A Callback

MSR Germany n-Hexane Gas Detector

MSR Germany n-Hexane Gas Detector
  • MSR Germany n-Hexane Gas Detector
  • MSR Germany n-Hexane Gas Detector
  • MSR Germany n-Hexane Gas Detector
  • MSR Germany n-Hexane Gas Detector
  • MSR Germany n-Hexane Gas Detector
  • MSR Germany n-Hexane Gas Detector
  • MSR Germany n-Hexane Gas Detector
  • MSR Germany n-Hexane Gas Detector
  • MSR Germany n-Hexane Gas Detector
  • MSR Germany n-Hexane Gas Detector
  • MSR Germany n-Hexane Gas Detector
  • MSR Germany n-Hexane Gas Detector
Get Best Quote
Product Price: Rs 40,000 / PieceGet Best Price

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-P3435-A--X-X
Weight200gms
BrandMSR Germany
Usage/ApplicationIndustrial
MaterialPolycarbonate Enclosure
Operating Voltage24VDC
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C6H14 Combustible gas.

The MC2-X-P3435-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C6H14  sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 



Additional Information:

  • Production Capacity: 1000
Yes! I am InterestedRequest A Callback

MSR Germany Iso/n-Butane Gas Detector

MSR Germany Iso/n-Butane Gas Detector
  • MSR Germany Iso/n-Butane Gas Detector
  • MSR Germany Iso/n-Butane Gas Detector
  • MSR Germany Iso/n-Butane Gas Detector
  • MSR Germany Iso/n-Butane Gas Detector
  • MSR Germany Iso/n-Butane Gas Detector
  • MSR Germany Iso/n-Butane Gas Detector
  • MSR Germany Iso/n-Butane Gas Detector
  • MSR Germany Iso/n-Butane Gas Detector
  • MSR Germany Iso/n-Butane Gas Detector
  • MSR Germany Iso/n-Butane Gas Detector
Get Best Quote
Product Price: Rs 40,000 / PieceGet Best Price

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-P3460-A-X-X
Weight200gms

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C4H10 Combustible gas.

The MC2-X-P3460-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C4H10 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 

 

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 4-6 weeks
Yes! I am InterestedRequest A Callback

MSR Germany Isobutyl Alcohol Gas Detector

MSR Germany Isobutyl Alcohol Gas Detector
  • MSR Germany Isobutyl Alcohol Gas Detector
  • MSR Germany Isobutyl Alcohol Gas Detector
  • MSR Germany Isobutyl Alcohol Gas Detector
  • MSR Germany Isobutyl Alcohol Gas Detector
  • MSR Germany Isobutyl Alcohol Gas Detector
Get Best Quote
Product Price: Rs 45,000 / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Product Brochure

Product Details:
Display TypeDigital
BrandMSR Germany
Model Name/NumberMC2-X-P3468-A-X-X
Weight200gms
Power24VDC
MaterialPolycarbonate Enclosure
Measurement Range0-100% LEL
Accuracy1% LEL
ColorGrey
Humidity Range5-95 % RH not condensing
Mounting TypeDepending on Gas

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C4H10O Combustible gas.

The MC2-X-P3468-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catalytic Pellistor C4H10O sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
Yes! I am InterestedRequest A Callback

MSR Ethanol Detector Transmitter for Distilleries and Breweries

MSR Ethanol Detector Transmitter for Distilleries and Breweries
  • MSR Ethanol Detector Transmitter for Distilleries and Breweries
  • MSR Ethanol Detector Transmitter for Distilleries and Breweries
  • MSR Ethanol Detector Transmitter for Distilleries and Breweries
  • MSR Ethanol Detector Transmitter for Distilleries and Breweries
Get Best Quote
Product Price: Rs 40,000 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Details:
BrandMSR Germany
Frequency0-100% LEL
Output Signal4~20 mA
MaterialFlameproof
Accuracy1%
Usage/ApplicationEthanol Vapor Detections
Country of OriginMade in India
OEMGermany

The MSR Ethanol Sensor Transmitter plays a vital role in ensuring safety, compliance, and operational efficiency in distilleries and breweries. Here's why it's so important:

1. Early Detection of Ethanol Vapors
  • Ethanol is highly flammable and volatile. Even low concentrations of vapor in the air can create an explosive atmosphere.

  • MSR’s ethanol sensor provides real-time monitoring, alerting personnel before vapor levels reach dangerous thresholds.

2. Fire and Explosion Prevention
  • In distilleries and breweries, ethanol leaks can result from:

    • Leaky equipment

    • Storage tank overflows

    • Poor ventilation

  • The sensor helps prevent fire hazards by triggering alarms or ventilation systems when ethanol vapor levels rise.

 Worker Health and Safety
  • Prolonged exposure to high ethanol concentrations can cause:

    • Dizziness

    • Respiratory irritation

    • Long-term health effects

  • MSR sensors help maintain a safe breathing environment, protecting workers’ health.

4. Compliance with Safety Regulations
  • Regulatory bodies (like OSHA, ATEX, or local fire codes) require:

    • Continuous gas monitoring

    • Explosion-proof installations

  • Using an MSR ethanol sensor helps comply with legal safety mandates, avoiding fines or shutdowns.

5. Integration with Alarm and Ventilation Systems
  • MSR sensors can connect with:

    • Exhaust fans

    • Fire suppression systems

    • Audible and visual alarms

  • This ensures automatic response to hazardous ethanol levels.

6. Trusted German Engineering
  • MSR-Electronic GmbH is known for:

    • High-quality sensors

    • Durable and precise instrumentation

  • Ideal for industrial environments like distilleries and breweries where reliability is critical.

Applications
  • Fermentation rooms

  • Ethanol storage tanks

  • Bottling and packaging lines

  • Barrel aging areas

  • Loading docks and tank farms

 Why Distilleries & Breweries Should Choose MSR:

“A single unnoticed ethanol leak can lead to disaster. MSR Ethanol Sensor Transmitters ensure your production remains safe, compliant, and uninterrupted.”

Also We will give you complete design Engineering Solutions under one roof. 



Additional Information:

  • Item Code: Ethanol-Sensor
  • Production Capacity: 1000
  • Delivery Time: 1week
Yes! I am InterestedRequest A Callback

MSR Germany Benzene Gas Detector

MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector
Get Best Quote
Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Product Details:
Display TypeDigital
BrandMSR Germany
Model Name/NumberMC2-X-P3430-A-X-X
Weight200gmd
Power24VDC
MaterialPolycarbonate
Measurement Range0-100%LEL
Accuracy1% LEL
Battery LifeNA
ColorGrey
Humidity Range5-95 % RH not condensing
Mounting TypeDepending on Gas Type
Shell MaterialPolycarbonate
Voltage24VDC

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C6H6 Flammable/Combustible gas.

The MC2-X-P3430-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical C6H6 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe - Gas Detectors and Alarm Systems



Additional Information:

  • Item Code: MC2-X-P3430-A-X-X
  • Production Capacity: 1000
  • Delivery Time: Ex-Stock or 4-6 weeks
Yes! I am InterestedRequest A Callback

MSR Germany Butadiene Gas Detector

MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector
Get Best Quote
Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Product Brochure

Product Details:
Display TypeOptional, Digital
BrandMSR Gerany
Model Name/NumberMC2-X-P3494-A-X-X
Weight200gms
Power24VDC
MaterialPolycarbonate Enclosure
Measurement Range0-100% LEL
Accuracy1% LEL
ColorGrey
Humidity Range5-95 % RH not condensing
Mounting TypeDepending On Gas Type
Signal Output4-20mA
Sensor TypeCatalytic Pellistor
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C4H6 Combustible/Flammable gas.

The MC2-X-E1110-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catlytic Pellistor C4H6 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
Yes! I am InterestedRequest A Callback

MSR Germany IECEx, ATEX, SIL2 Acetone Gas Detector

MSR Germany IECEx, ATEX, SIL2 Acetone Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Acetone Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Acetone Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Acetone Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Acetone Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Acetone Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Acetone Gas Detector
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Gas TypeCombustible Gas
Usage/ApplicationGas Detection
Display TypeAnalog, Digital
Model Name/NumberAcetone Gas Detector
Weight1.2 Kg
BrandMSR Germany
Measurement Range0-100% LEL
Power24VDC
MaterialAluminium di caste
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 2-8 weeks
Yes! I am InterestedRequest A Callback

MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector

MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Display TypeDigital, Analog
BrandMSR Germany
Weight1.2 Kg
Model Name/NumberMethanol Gas Detector
Power24VDC
MaterialAluminium di cast
Accuracy1%
Measurement Range0-100% LEL
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Production Capacity: 100
  • Delivery Time: 2-8 weeks
Yes! I am InterestedRequest A Callback

MSR Germany IECEx, ATEX, SIL2 Ethane Gas Detector

MSR Germany IECEx, ATEX, SIL2 Ethane Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Ethane Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Ethane Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Ethane Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Ethane Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Ethane Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Ethane Gas Detector
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Display TypeDigital, Analog
Model Name/NumberEthane Gas Detector
Weight1.2 Kg
BrandMSR Germany
Measurement Range0-100% LEL
Power24VDC
MaterialAluminium di cast
Accuracy1%
  • PX2 1 series with Ex db protection for Zone 1 and 2
  • PX2 2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4 20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
  • PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4 20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please 



Additional Information:

  • Delivery Time: 2-8 weeks
Yes! I am InterestedRequest A Callback

MSR Germany Iso/n-Pentane Gas Detector

MSR Germany Iso/n-Pentane Gas Detector
  • MSR Germany Iso/n-Pentane Gas Detector
  • MSR Germany Iso/n-Pentane Gas Detector
  • MSR Germany Iso/n-Pentane Gas Detector
  • MSR Germany Iso/n-Pentane Gas Detector
  • MSR Germany Iso/n-Pentane Gas Detector
  • MSR Germany Iso/n-Pentane Gas Detector
  • MSR Germany Iso/n-Pentane Gas Detector
  • MSR Germany Iso/n-Pentane Gas Detector
  • MSR Germany Iso/n-Pentane Gas Detector
  • MSR Germany Iso/n-Pentane Gas Detector
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Minimum Order Quantity10 Piece
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-P3475-A-X-X
Weight200gms
BrandMSR Germany
Measurement Range0-100% LEL
Power24VDC
MaterialPolycarbonate Enclosure

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C5H12 Combustible gas.

The MC2-X-P3475-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C5H12  sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
Yes! I am InterestedRequest A Callback

MSR Germany Methyl Acetate Gas Detector

MSR Germany Methyl Acetate Gas Detector
  • MSR Germany Methyl Acetate Gas Detector
  • MSR Germany Methyl Acetate Gas Detector
  • MSR Germany Methyl Acetate Gas Detector
  • MSR Germany Methyl Acetate Gas Detector
  • MSR Germany Methyl Acetate Gas Detector
  • MSR Germany Methyl Acetate Gas Detector
  • MSR Germany Methyl Acetate Gas Detector
  • MSR Germany Methyl Acetate Gas Detector
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-P3473-A-X-X
BrandMSR Germany
Measurement Range0-100% LEL
Usage/ApplicationIndustrial
MaterialPolycarbonate Enclosure
Operating Voltage24VDC
ColorGrey
Mounting TypeDepending on Gas
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C3H6O2 Combustible gas.

The MC2-X-P3473-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C3H6O2 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 378
      o EN 45544
      o EN 50104 (for O2)
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 

 



Additional Information:

  • Production Capacity: 1000
Yes! I am InterestedRequest A Callback

MSR Germany n-Heptane Gas Detector

MSR Germany n-Heptane Gas Detector
  • MSR Germany n-Heptane Gas Detector
  • MSR Germany n-Heptane Gas Detector
  • MSR Germany n-Heptane Gas Detector
  • MSR Germany n-Heptane Gas Detector
  • MSR Germany n-Heptane Gas Detector
  • MSR Germany n-Heptane Gas Detector
  • MSR Germany n-Heptane Gas Detector
  • MSR Germany n-Heptane Gas Detector
  • MSR Germany n-Heptane Gas Detector
  • MSR Germany n-Heptane Gas Detector
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-P3491-A-X-X
Weight200gms
BrandMSR Germany
Usage/ApplicationIndustrial
Operating Voltage24VDC
MaterialPolycarbonate Enclosure
Sensor TypeCatalytic Pellistor
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C7H16 Combustible gas.

The MC2-X-P3491-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C7H16 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 378
      o EN 45544
      o EN 50104 (for O2)
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 



Additional Information:

  • Production Capacity: 1000
Yes! I am InterestedRequest A Callback

MSR Germany Nonane Gas Detector

MSR Germany Nonane Gas Detector
  • MSR Germany Nonane Gas Detector
  • MSR Germany Nonane Gas Detector
  • MSR Germany Nonane Gas Detector
  • MSR Germany Nonane Gas Detector
  • MSR Germany Nonane Gas Detector
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Gas TypeCombustible Gas
BrandMSR Germany
Model Name/NumberMC2-X-P3495-A-X-X
Sensor TypeCatalytic Pellistor
Usage/ApplicationIndustrial
Voltage24VDC
Weight200gms
Display TypeDigital
Measurement Range0-100% LEL
ColorGrey
MaterialPolycarbonate Enclosure

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C9H20 Combustible gas.

Tiche MC2-X-P3495-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C9H20 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.

 



Additional Information:

  • Production Capacity: 1000
Yes! I am InterestedRequest A Callback

MSR Germany Octane Gas Detector

MSR Germany Octane Gas Detector
  • MSR Germany Octane Gas Detector
  • MSR Germany Octane Gas Detector
  • MSR Germany Octane Gas Detector
  • MSR Germany Octane Gas Detector
  • MSR Germany Octane Gas Detector
  • MSR Germany Octane Gas Detector
  • MSR Germany Octane Gas Detector
  • MSR Germany Octane Gas Detector
  • MSR Germany Octane Gas Detector
  • MSR Germany Octane Gas Detector
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-P3470-A-X-X
Weight200gms
Usage/ApplicationIndustrial
BrandMSR Germany
ColorGrey

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C8H18 Combustible gas.

The MC2-X-P3470-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C8H18 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 



Additional Information:

  • Production Capacity: 1000
Yes! I am InterestedRequest A Callback

MSR Germany Petrol Vapours Detector

MSR Germany Petrol Vapours Detector
  • MSR Germany Petrol Vapours Detector
  • MSR Germany Petrol Vapours Detector
  • MSR Germany Petrol Vapours Detector
  • MSR Germany Petrol Vapours Detector
  • MSR Germany Petrol Vapours Detector
  • MSR Germany Petrol Vapours Detector
  • MSR Germany Petrol Vapours Detector
  • MSR Germany Petrol Vapours Detector
  • MSR Germany Petrol Vapours Detector
  • MSR Germany Petrol Vapours Detector
  • MSR Germany Petrol Vapours Detector
  • MSR Germany Petrol Vapours Detector
  • MSR Germany Petrol Vapours Detector
  • MSR Germany Petrol Vapours Detector
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Minimum Order Quantity10 Piece
Gas TypeCombustible Gas
Usage/ApplicationIndustrial
Display TypeDigital
Model Name/NumberMC2-X-P3460-A-X-X
Weight200gms
BrandMSR Germany
Measurement Range0-100% LEL
Power24VDC
MaterialPolycarbonate Enclosure
Humidity5-95 % RH not condensing
Response Time< 15 sec. (CH4)
ColorGrey
Mounting TypeDepending on Gas
Sensor TypeCatalytic Pellistor
Output CurrentAnalog 4-20mA
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Petrol Vapours.

The MC2-X-P3496-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Petrol Vapours sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 



Additional Information:

  • Production Capacity: 1000
Yes! I am InterestedRequest A Callback

MSR Germany Propane Gas Detector

MSR Germany Propane Gas Detector
  • MSR Germany Propane Gas Detector
  • MSR Germany Propane Gas Detector
  • MSR Germany Propane Gas Detector
  • MSR Germany Propane Gas Detector
  • MSR Germany Propane Gas Detector
  • MSR Germany Propane Gas Detector
  • MSR Germany Propane Gas Detector
  • MSR Germany Propane Gas Detector
  • MSR Germany Propane Gas Detector
  • MSR Germany Propane Gas Detector
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-P3480-A-X-X
Weight200gms
BrandMSR Germany
Usage/ApplicationIndustrial
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C3H8 Combustible gas.

The MC2-X-P3480-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C3H8 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 



Additional Information:

  • Production Capacity: 10000
Yes! I am InterestedRequest A Callback

MSR Germany Ethyl acetate Gas Detector

MSR Germany Ethyl acetate Gas Detector
  • MSR Germany Ethyl acetate Gas Detector
  • MSR Germany Ethyl acetate Gas Detector
Get Best Quote
Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec.
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeOptional, Digital
BrandMSR Germany
Model Name/NumberMC2-X-P3427-A-X
Weight200gms
Power24VDC
Usage/ApplicationIndustrial
MaterialPolycarbonate Enclosure
Operating Voltage24VDC
Measurement Range0-100% LEL
Accuracy1% LEL
ColorGrey
Humidity Range5-95 % RH not condensing
Mounting TypeDepending on Gas Type
Voltage24VDC
Signal OutputAnalog 4-20mA
I Deal InNew Only

μGard 2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C4H8O2 Combustible gas.

The MC2-X-P3427-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C4H8O2 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35 degreeC
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
       EN 50271
       EN 50545
       EN 61010-1
       ANSI/UL 61010 1
       CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe - Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: Ex Stock or 4-6 Weeks
Yes! I am InterestedRequest A Callback

View More

EXPLORE MORE CATEGORIES

© ALVI Automation India Private Limited. All Rights Reserved (Terms of Use)Developed and managed by IndiaMART InterMESH Ltd.