MSR Germany Methyl Ethyl Ketone Gas Detector
Product Brochure
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | 5-95 % RH not condensing |
Measuring Range | 0-100% LEL |
Response Time | < 15 sec. (CH4) |
Storage Temperature | +5 DegreeC to +30 DegreeC |
Brand | MSR Germany |
Model Name/Number | MC2-X-P3458-A-X-X |
Usage/Application | Industrial |
Color | Grey |
Measurement Range | 0-100% LEL |
I Deal In | New Only |
Signal Output | Analog 4-20mA |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C4H8O Combustible gas.
The MC2-X-P3458-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C4H8O sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Additional Information:
- Production Capacity: 1000
Flameproof Petrol Diesel Vapours Sensor Transmitter
Product Brochure
Display Type | Digital, Analog |
Model Name/Number | Petrol Diesel Detector |
Weight | 1.2 Kg |
Brand | MSR Germany |
Measurement Range | 0-100% LEL |
Power | 24VDC |
Material | Aluminium |
Accuracy | 1% |
ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world-class cutting edge Flameproof Petrol Vapours Gas Detector Transmitter and Monitor.
We are involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.
Description:
Ex-proof Petrol Vapours Sensor Transmitter and Monitor is a highly robust, industrial grade, flameproof, or explosion-proof gas detector for Flammable Petrol/Diesel Vapours detection in % LEL monitoring & Control Systems.
The detector is used for online, continuous monitoring of the Flammable Gases in ambient air or duct or pipeline. It is ATEX, IECEx certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.
With Benefits:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- For zone 1 (and also suitable for zone 2) Type Ex db with flame-proof enclosure
- For zone 2: Type Ex nA with flame-proof enclosure
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4 20 mA output
- Serial interface to the control centre
- Reverse polarity protection
- Overload protection
- LCD with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
Our customers come from various industries like oil/gas, chemical, manufacturing, petrochemical, pharmaceutical, building, mining, nuclear, steel, defense, power, water, wastewater, mining, cement, dairy, automobile, etc.
Additional Information:
- Production Capacity: 100
- Delivery Time: 2 to 8 weeks
MSR Germany IECEx, ATEX, SIL2 Hydrogen Gas Detector
Product Brochure
Display Type | Analog, Digital |
Measurement Range | 0-100 % LEL |
Brand | MSR Germany |
Model Name/Number | Flamepoof Hydrogen Gas Detector |
Power Source | 24vdc |
Driven Type | Continuous Detection |
Color | Grey Aluminium |
Material | Aluminium Di cast |
Voltage | 24vdc |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4 20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
- PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4 20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter,
Additional Information:
- Delivery Time: 2-8 weeks
Ammonia Gas Sensor Transmitter
Product Brochure
Operating Temperature | -30 DegreeC to +60 DegreeC (-22 DegreeF to 140 DegreeF) |
Gas Type | Combustible Gas |
Operating Humidity | 5-95 % RH not condensing |
Brand | MSR Germany |
Expected Operating Life | NA |
Model Name/Number | MC2-X-P3408-A-X-X |
Measuring Range | 0-100%LEL |
Sensor Type | Catalytic Pellistor |
Usage/Application | Industrial |
Voltage | 24VDC |
Weight | 200gms |
Display Type | Optional |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect NH3 Flammable/Combustible gas.
The MC2-X-P3408-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catalytic Pellistor Bead Sensor NH3 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Item Code: MC2-X-P3408-A-X-X
- Production Capacity: 1000
- Delivery Time: Ex-Stock or 4-6 Weeks
Toluene Gas Detector and Monitor (C7H8)
Product Brochure
Display Type | Analog |
Brand | MSR Electronics |
Model Name/Number | PX2-X-XXXX-X-X |
Weight | 1.5 Kg |
Power | 24VDC |
Material | Aluminium die-casting or SS |
Accuracy | +/- 1% LEL |
Measurement Range | % LEL |
Status Indication | Yes |
Battery Life | NA |
Voltage | 24VDC |
Warranty | 1 year |
Signal Output | 4-20mA |
We are is involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.
FEATURES:
• ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection• Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay• For zone 1 (and also suitable for zone 2) Type “Ex db” with flame-proof enclosure• For zone 2: Type “Ex nA” with flame-proof enclosure• Continuous monitoring• Microprocessor with 12-bit converter resolution• Self-monitoring system• Easy calibration• Calibration service by exchanging the sensor head• Proportional 4–20 mA output• Serial interface to the control centre• Reverse polarity protection• Overload protection• LCD with status LEDs (optional)• Alarm and fault signal relay (optional)
Application:
• Coal mines, underground mines• Oil & gas, refinery• Fertilizer industry• Landfill gases• Sewage treatment plants (STP), effluent treatment facility• Cryogenic application• Chemical, petrochemical industry• Food processing industry• Furnace, burner application• Gas reticulation system
#TolueneDetector #Toluene Monitor #C7H8Detector #C7H8Monitor#FlammableLiquid#ExplosiveGas#FlammableGas#SolventMonitoring#ATEX#SIL2#IECEx #PESO #CCOE #DGMS #CMRI#Intrinsicallysafe#ExplosionProof#FlameProof#ZONE1#ZONE2#IECExCertified#ATEXCertified#SIL2Certified#HARTProtocol#ATEXGasDetector#ExplosionProof#ExplosiveGas#FlameproofGasDetector#FlameproofGasSensor#FlammableGas#Gasdetector#Gassensor#LEL#VOL#Detector#SIL2#Zone1#Zone2#Accessories #Adapter#Calibration #CalibrationGas#CellarAlarm #DigitalBusSensors #EnvironmentalMonitoring #FlameDetector#Fumigation #FumigationProducts#GasAlarm #GasControllers #GasDetectorTubes #GasTransmitters#GasSensorTransmitters#HandPumpsAccessories#HandTool#HazardousAre #IndoorAirQuality #MAPAnalysers #PolyGard2 #PolyXeta2 #Standalone #μGard2MC2Series#JunctionBO #JunctionBOXCopperFree#JunctionBoxMarineGrade#MarineGradeEnlosure#StainlessSteelEclocsure#StainlessSteelHousing#12BitConverterResolution#ExnA#Exdb#ElectricalExprotected#MetrologicalTesting#RS485#HART#Relay#LED#LCD#Continuousmonitoring#SelfMonitoringSystem#Easycalibration#Calibrationservice#exchanging#sensorhead#PlugPlay#4to20mAoutput#SerialInterface#ReversePolarityProtection#OverloadProtection#LCDDisplay#StatusLEDs #AlarmRelay#FaultSignalRelay
MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
Product Brochure
Display Type | Digital, Analog |
Brand | MSR Germany |
Weight | 1.2 Kg |
Model Name/Number | Propane Gas Leak Detection |
Power | 24VDC |
Material | Aluminium di caste |
Measurement Range | 0-100% LEL |
Accuracy | 1% |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
Additional Information:
- Delivery Time: 2-8 weeks
MSR Germany IECEx, ATEX, SIL2 Cyclopentane Gas Sensor
Product Brochure
Operating Temperature | -20-50 |
Operating Humidity | 95% |
Expected Operating Life | 3-5 years |
Measuring Range | 0-100% LEL |
Response Time | 10 second |
Display Type | Digital, Analog |
Model Name/Number | Cyclopentane Gas Sensor |
Weight | 1.2 Kg |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
Additional Information:
- Delivery Time: 2-8 weeks
MSR Germany IECEx, ATEX, SIL2 Octane Gas Sensor
Product Brochure
Display Type | Digital, Analog |
Brand | MSR Germany |
Weight | 1.2 Kg |
Model Name/Number | Octane Gas Sensor |
Power | 24VDC |
Material | Aluminium di cast |
Measurement Range | 0-100% LEL |
Accuracy | 1% |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
Additional Information:
- Delivery Time: 2-8 weeks
MSR Germany Ex-Proof Nonane Sensor Transmitter
Minimum Order Quantity | 1 Piece |
Display Type | Digital, Analog |
Output Signal | 4-20mA |
Model Name/Number | Nonane Gas Detector |
Weight | 1.2 Kg |
Brand | MSR Germany |
ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world-class cutting edge Flameproof Nonane Gas Detector Transmitter and Monitor.
We are involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.
Description:
Ex-proof Nonane (C9H20) Gas Detector Transmitter and Monitor is a highly robust, industrial grade, flameproof, or explosion-proof gas detector for Flameproof C9H20 gas or Nonane detection in % LEL monitoring & Control Systems.
The detector is used for online, continuous monitoring of the Nonane Combustible Gases in ambient air or duct or pipeline. It is ATEX, IECEx certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.
With Benefits:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- For zone 1 (and also suitable for zone 2) Type Ex db with flame-proof enclosure
- For zone 2: Type Ex nA with flame-proof enclosure
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4 20 mA output
- Serial interface to the control centre
- Reverse polarity protection
- Overload protection
- LCD with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
Our customers come from various industries like oil/gas, chemical, manufacturing, petrochemical, pharmaceutical, building, mining, nuclear, steel, defense, power, water, wastewater, mining, cement, dairy, automobile, etc.
Additional Information:
- Production Capacity: 1000
- Delivery Time: 2-8weeks
MSR Germany n-Heptane Gas Sensor
Product Brochure
Operating Temperature | -20-50 |
Operating Humidity | 95% |
Expected Operating Life | 3-5 years |
Measuring Range | 0-100% LEL |
Response Time | 10 second |
Display Type | Digital, Analog |
Model Name/Number | n-Heptane Gas Sensor |
Weight | 1.2 Kg |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
Additional Information:
- Production Capacity: 100
- Delivery Time: 2-8 weeks
MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor
Product Brochure
Operating Temperature | -20-50 |
Operating Humidity | 95% |
Expected Operating Life | 3-5 years |
Measuring Range | 0-100% LEL |
Response Time | 10 second |
Display Type | Analog, Digital |
Brand | MSR Germany |
Weight | 1.2 Kg |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
Additional Information:
- Production Capacity: 1000
- Delivery Time: 2-8 weeks
MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
Product Brochure
Display Type | Digital, Analog |
Brand | MSR Germany |
Weight | 1.2 Kg |
Model Name/Number | Propane Gas Leak Detection |
Power | 24VDC |
Material | Aluminium di caste |
Accuracy | 1% |
Measurement Range | 0-5000 ppm |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
Additional Information:
- Delivery Time: 2-8 weeks
MSR Germany IECEx, ATEX, SIL2 Methyl Acetate Gas Sensor
Product Brochure
Display Type | Digital, Analog |
Brand | MSR Germany |
Gas Type | Combustible Gas |
Model Name/Number | Methyl Acetate Gas Sensor |
Power | 24VDC |
Weight | 1.2 kg |
Sensor Type | LPG |
Voltage | 24vdc |
Usage/Application | Gas Detection |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
Additional Information:
- Delivery Time: 2-8 weeks
IECEx, ATEX, SIL2 Butadiene Gas Detector
Product Brochure
Display Type | Digital, Analog |
Brand | MSR Germany |
Model Name/Number | Butadiene Sensor |
Weight | 1.2 Kg |
Power | 24VDC |
Material | Aluminium di cate |
Accuracy | 1% |
Measurement Range | 0-100% |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
Additional Information:
- Production Capacity: 100
- Delivery Time: 2-8 weeks
MSR Germany IECEx, ATEX, SIL2 Acetone Gas Detector
Product Brochure
Minimum Order Quantity | 1 Piece |
Gas Type | Combustible Gas |
Usage/Application | Gas Detection |
Display Type | Digital, Analog |
Model Name/Number | Acetone Gas Detector |
Weight | 1.2 Kg |
Brand | MSR Germany |
Measurement Range | 0-100% LEL |
Power | 24VDC |
Material | Aluminium di caste |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
Additional Information:
- Production Capacity: 1000
- Delivery Time: 2-8 weeks
MSR Germany IECEx, ATEX, SIL2 Ethane Gas Detector
Product Brochure
Minimum Order Quantity | 1 Piece |
Display Type | Digital, Analog |
Model Name/Number | Ethane Gas Detector |
Weight | 1.2 Kg |
Brand | MSR Germany |
Measurement Range | 0-100% LEL |
Power | 24VDC |
Material | Aluminium di cast |
Accuracy | 1% |
- PX2 1 series with Ex db protection for Zone 1 and 2
- PX2 2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4 20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
- PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4 20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please
Additional Information:
- Delivery Time: 2-8 weeks
MSR Germany Cyclohexane Gas Detector
Minimum Order Quantity: 10 Piece
Product Brochure
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | 5-95 % RH not condensing |
Measuring Range | 0-100% LEL |
Response Time | < 15 sec. |
Storage Temperature | +5 DegreeC to +30 DegreeC |
Display Type | Digital, Optional |
Brand | MSR Germany |
Weight | 200gms |
Model Name/Number | MC2-X-P3415-A-X-X |
Power | 24VDC |
Usage/Application | Industrial |
Operating Voltage | 24VDC |
Material | Poycarbonate Enclosure |
Measurement Range | 0-100%LEL |
Accuracy | 1% LEL |
Digital Output | NO |
Color | Grey |
Humidity Range | 5-95 % RH not condensing |
Mounting Type | Depending On Gas Type |
Voltage | 24VDC |
Signal Output | Analog 4-20mA |
Sensor Type | Catalytic Pellistor |
I Deal In | New Only |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C6H12 Combustible gas.
The MC2-X-P3415-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Cataylitic Pellistor C6H12 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Production Capacity: 1000
- Delivery Time: Ex Stock or 4-6 Weeks
MSR Germany Butyl Acetate Gas Detector
Minimum Order Quantity: 1 Piece
Product Brochure
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | +5 DegreeC to +30 DegreeC |
Measuring Range | 0-100% LEL |
Response Time | < 15 sec. |
Storage Temperature | +5 DegreeC to +30 DegreeC |
Display Type | Optional, Digital |
Brand | MSR Germany |
Model Name/Number | MC2-X-P3448-A-X-X |
Weight | 200gms |
Power | 24VDC |
Usage/Application | Industrial |
Operating Voltage | 24VDC |
Material | Polycarbonate Enclosure |
Accuracy | 1% LEL |
Measurement Range | 0-100%LEL |
Color | Grey |
Shell Material | Polycarbonate |
Signal Output | Analog 4-20mA |
I Deal In | New Only |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C6H12O2 Combustible gas.
The MC2-X-E1110-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catalytic Pellistor C6H12O2 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Item Code: MC2-X-P3448-A-X-X
- Production Capacity: 1000
- Delivery Time: Ex-Stock or 4-6 weeks
MSR Germany Cyclopentane Gas Detector
Product Brochure
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | 5-95 % RH not condensing |
Measuring Range | 0-100% LEL |
Response Time | < 15 sec. |
Storage Temperature | +5 DegreeC to +30 DegreeC |
Display Type | Digital, Optional |
Model Name/Number | MC2-X-X-P3472-A-X |
Weight | 200gms |
Measurement Range | 0-100% LEL |
Power | 24VDC |
Usage/Application | Industrial |
Operating Voltage | 24VDC |
Brand | MSR Germany |
Color | Grey |
Accuracy | 1% LEL |
Humidity Range | 5-95 % RH not condensing |
Material | Polycarbonate |
I Deal In | New Only |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C5H10 Combustible gas.
The MC2-X-P3472-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catalytic Pellisytor C5H10 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Production Capacity: 1000
MSR Germany Ethane Gas Detector
Product Brochure
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | 5-95 % RH not condensing |
Measuring Range | 0-100% LEL |
Response Time | < 15 sec. |
Storage Temperature | +5 DegreeC to +30 DegreeC |
Display Type | Optional, Digital |
Model Name/Number | MC2-X-P3420-A-X-X |
Weight | 200gms |
Brand | MSR Germany |
Measurement Range | 0-100% LEL |
Power | 24VDC |
Usage/Application | Industrial |
Material | Polycarbonate Enclosure |
Operating Voltage | 24VDC |
Accuracy | 1% LEL |
Color | Grey |
Humidity Range | 5-95 % RH not condensing |
Mounting Type | Depending on Gas Type |
I Deal In | New Only |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C2H6 Combustible gas.
The MC2-X-P3420-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C2H6 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Production Capacity: 1000
MSR Germany Ethyl Alcohol Gas Detector
Minimum Order Quantity: 10 Piece
Product Brochure
Gas Type | Combustible Gas |
Usage/Application | Industrial |
Display Type | Digital |
Brand | MSR Germany |
Weight | 200gms |
Model Name/Number | MC2-X-P3425-A-X-X |
Power | 24VDC |
Material | Polycarbonate Enclosure |
Humidity | 5-95 % RH not condensing |
Response Time | < 15 sec. (CH4) |
Accuracy | 1% LEL |
Measurement Range | 0-100% LEL |
Humidity Range | 5-95 % RH not condensing |
Mounting Type | Depending on Gas |
Voltage | 24VDC |
Gases Measured | Ethyl alcohol,C2H5OH |
I Deal In | New Only |
Sensing Element | Catalytic Pellistor |
Place Of Origin | Germany |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C2H5OH Combustible gas.
The MC2-X-P3425-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C2H5OH sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe - Gas Detectors and Alarm Systems
Additional Information:
- Production Capacity: 1000
- Delivery Time: Ex stock or 4-6 Weeks
MSR Germany Ethylene Gas Detector
Product Brochure
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | 5-95 % RH not condensing |
Measuring Range | 0-100% LEL |
Response Time | < 15 sec. (CH4) |
Storage Temperature | +5 DegreeC to +30 DegreeC |
Display Type | Digital |
Model Name/Number | MC2-X-X-P3410-A-X |
Weight | 200gms |
Brand | MSR Germany |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C2H4 Combustible gas.
The MC2-X-P3410-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C2H4 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Production Capacity: 1000
Msr Germany Methane Gas Detector
Product Brochure
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | 5-95 % RH not condensing |
Measuring Range | 0-100% LEL |
Response Time | < 15 sec. (CH4) |
Storage Temperature | +5 DegreeC to +30 DegreeC |
Display Type | Digital |
Model Name/Number | MC2-X-P3400-A-X-X |
Weight | 200gms |
Power | 24VDC |
Usage/Application | Industrial |
Brand | MSR Germany |
Color | Grey |
I Deal In | New Only |
Sensor Type | Catalytic Pellistor |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Methane Combustible gas.
The MC2-X-P3400-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the CH4 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Additional Information:
- Production Capacity: 1000
MSR Germany Methanol Gas Detector
Product Brochure
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | 5-95 % RH not condensing |
Measuring Range | 0-100% LEL |
Response Time | < 15 sec. (CH4) |
Storage Temperature | +5 DegreeC to +30 DegreeC |
Display Type | Digital |
Model Name/Number | MC2-X-P3450-A-X-X |
Weight | 200gms |
Measurement Range | 0-100% LEL |
Power | 24VDC |
Usage/Application | Industrial |
Brand | MSR Germany |
Color | Grey |
Mounting Type | Depending on Gas Type |
I Deal In | New Only |
Sensor Type | Catalytic Pellistor |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect CH3OH Combustible gas.
The MC2-X-P3450-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the CH3OH module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Additional Information:
- Production Capacity: 1000
MSR Germany Methyl Acetate Gas Detector
Product Brochure
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | 5-95 % RH not condensing |
Measuring Range | 0-100% LEL |
Response Time | < 15 sec. (CH4) |
Storage Temperature | +5 DegreeC to +30 DegreeC |
Display Type | Digital |
Model Name/Number | MC2-X-P3473-A-X-X |
Brand | MSR Germany |
Measurement Range | 0-100% LEL |
Usage/Application | Industrial |
Material | Polycarbonate Enclosure |
Operating Voltage | 24VDC |
Color | Grey |
Mounting Type | Depending on Gas |
I Deal In | New Only |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C3H6O2 Combustible gas.
The MC2-X-P3473-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C3H6O2 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Additional Information:
- Production Capacity: 1000
MSR Germany n-Hexane Gas Detector
Product Brochure
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | 5-95 % RH not condensing |
Measuring Range | 0-100% LEL |
Response Time | < 15 sec. (CH4) |
Storage Temperature | +5 DegreeC to +30 DegreeC |
Display Type | Digital |
Model Name/Number | MC2-X-P3435-A--X-X |
Weight | 200gms |
Brand | MSR Germany |
Usage/Application | Industrial |
Material | Polycarbonate Enclosure |
Operating Voltage | 24VDC |
I Deal In | New Only |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C6H14 Combustible gas.
The MC2-X-P3435-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C6H14 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Additional Information:
- Production Capacity: 1000
MSR Germany Nonane Gas Detector
Product Brochure
Gas Type | Combustible Gas |
Brand | MSR Germany |
Model Name/Number | MC2-X-P3495-A-X-X |
Sensor Type | Catalytic Pellistor |
Usage/Application | Industrial |
Voltage | 24VDC |
Weight | 200gms |
Display Type | Digital |
Measurement Range | 0-100% LEL |
Color | Grey |
Material | Polycarbonate Enclosure |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C9H20 Combustible gas.
Tiche MC2-X-P3495-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C9H20 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
Additional Information:
- Production Capacity: 1000
MSR Germany Petrol Vapours Detector
Product Brochure
Minimum Order Quantity | 10 Piece |
Gas Type | Combustible Gas |
Usage/Application | Industrial |
Display Type | Digital |
Model Name/Number | MC2-X-P3460-A-X-X |
Weight | 200gms |
Brand | MSR Germany |
Measurement Range | 0-100% LEL |
Power | 24VDC |
Material | Polycarbonate Enclosure |
Humidity | 5-95 % RH not condensing |
Response Time | < 15 sec. (CH4) |
Color | Grey |
Mounting Type | Depending on Gas |
Sensor Type | Catalytic Pellistor |
Output Current | Analog 4-20mA |
I Deal In | New Only |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Petrol Vapours.
The MC2-X-P3496-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Petrol Vapours sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Additional Information:
- Production Capacity: 1000
MSR Germany Iso/n-Butane Gas Detector
Product Brochure
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | 5-95 % RH not condensing |
Measuring Range | 0-100% LEL |
Response Time | < 15 sec. (CH4) |
Storage Temperature | +5 DegreeC to +30 DegreeC |
Display Type | Digital |
Model Name/Number | MC2-X-P3460-A-X-X |
Weight | 200gms |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C4H10 Combustible gas.
The MC2-X-P3460-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C4H10 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Production Capacity: 1000
- Delivery Time: 4-6 weeks
MSR Germany Isobutyl Alcohol Gas Detector
Minimum Order Quantity: 10 Piece
Product Brochure
Display Type | Digital |
Brand | MSR Germany |
Model Name/Number | MC2-X-P3468-A-X-X |
Weight | 200gms |
Power | 24VDC |
Material | Polycarbonate Enclosure |
Measurement Range | 0-100% LEL |
Accuracy | 1% LEL |
Color | Grey |
Humidity Range | 5-95 % RH not condensing |
Mounting Type | Depending on Gas |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C4H10O Combustible gas.
The MC2-X-P3468-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catalytic Pellistor C4H10O sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Production Capacity: 1000
MSR Germany Butadiene Gas Detector
Minimum Order Quantity: 10 Piece
Product Brochure
Display Type | Digital, Optional |
Brand | MSR Gerany |
Model Name/Number | MC2-X-P3494-A-X-X |
Weight | 200gms |
Power | 24VDC |
Material | Polycarbonate Enclosure |
Accuracy | 1% LEL |
Measurement Range | 0-100% LEL |
Color | Grey |
Humidity Range | 5-95 % RH not condensing |
Mounting Type | Depending On Gas Type |
Signal Output | 4-20mA |
Sensor Type | Catalytic Pellistor |
I Deal In | New Only |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C4H6 Combustible/Flammable gas.
The MC2-X-E1110-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catlytic Pellistor C4H6 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Production Capacity: 1000
MSR Germany Benzene Gas Detector
Minimum Order Quantity: 1 Piece
Product Brochure
Display Type | Digital |
Brand | MSR Germany |
Weight | 200gmd |
Model Name/Number | MC2-X-P3430-A-X-X |
Power | 24VDC |
Material | Polycarbonate |
Measurement Range | 0-100%LEL |
Accuracy | 1% LEL |
Battery Life | NA |
Color | Grey |
Humidity Range | 5-95 % RH not condensing |
Mounting Type | Depending on Gas Type |
Shell Material | Polycarbonate |
Voltage | 24VDC |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C6H6 Flammable/Combustible gas.
The MC2-X-P3430-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical C6H6 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe - Gas Detectors and Alarm Systems
Additional Information:
- Item Code: MC2-X-P3430-A-X-X
- Production Capacity: 1000
- Delivery Time: Ex-Stock or 4-6 weeks
MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
Product Brochure
Display Type | Digital, Analog |
Brand | MSR Germany |
Weight | 1.2 Kg |
Model Name/Number | Methanol Gas Detector |
Power | 24VDC |
Material | Aluminium di cast |
Measurement Range | 0-100% LEL |
Accuracy | 1% |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
Additional Information:
- Production Capacity: 100
- Delivery Time: 2-8 weeks
MSR Germany Iso/n-Pentane Gas Detector
Product Brochure
Minimum Order Quantity | 10 Piece |
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | 5-95 % RH not condensing |
Measuring Range | 0-100% LEL |
Response Time | < 15 sec. (CH4) |
Storage Temperature | +5 DegreeC to +30 DegreeC |
Display Type | Digital |
Model Name/Number | MC2-X-P3475-A-X-X |
Weight | 200gms |
Brand | MSR Germany |
Measurement Range | 0-100% LEL |
Power | 24VDC |
Material | Polycarbonate Enclosure |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C5H12 Combustible gas.
The MC2-X-P3475-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C5H12 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
Additional Information:
- Production Capacity: 1000
MSR Germany n-Heptane Gas Detector
Product Brochure
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | 5-95 % RH not condensing |
Measuring Range | 0-100% LEL |
Response Time | < 15 sec. (CH4) |
Storage Temperature | +5 DegreeC to +30 DegreeC |
Display Type | Digital |
Model Name/Number | MC2-X-P3491-A-X-X |
Weight | 200gms |
Brand | MSR Germany |
Usage/Application | Industrial |
Operating Voltage | 24VDC |
Material | Polycarbonate Enclosure |
Sensor Type | Catalytic Pellistor |
I Deal In | New Only |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C7H16 Combustible gas.
The MC2-X-P3491-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C7H16 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Additional Information:
- Production Capacity: 1000
MSR Germany Octane Gas Detector
Product Brochure
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | 5-95 % RH not condensing |
Measuring Range | 0-100% LEL |
Response Time | < 15 sec. (CH4) |
Storage Temperature | +5 DegreeC to +30 DegreeC |
Display Type | Digital |
Model Name/Number | MC2-X-P3470-A-X-X |
Weight | 200gms |
Usage/Application | Industrial |
Brand | MSR Germany |
Color | Grey |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C8H18 Combustible gas.
The MC2-X-P3470-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C8H18 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Additional Information:
- Production Capacity: 1000
MSR Germany Propane Gas Detector
Product Brochure
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | 5-95 % RH not condensing |
Measuring Range | 0-100% LEL |
Response Time | < 15 sec. (CH4) |
Storage Temperature | +5 DegreeC to +30 DegreeC |
Display Type | Digital |
Model Name/Number | MC2-X-P3480-A-X-X |
Weight | 200gms |
Brand | MSR Germany |
Usage/Application | Industrial |
I Deal In | New Only |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C3H8 Combustible gas.
The MC2-X-P3480-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C3H8 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Additional Information:
- Production Capacity: 10000
MSR Germany IECEx, ATEX, SIL2 n- Pentane Gas Sensor
Product Brochure
Display Type | Digital, Analog |
Model Name/Number | n- Pentane Gas Sensor |
Weight | 1.2 Kg |
Brand | MSR Germany |
Measurement Range | 0-100% LEL |
Power | 24VDC |
Material | Aluminium di cast |
Accuracy | 1% |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
Additional Information:
- Production Capacity: 100
- Delivery Time: 2-8 weeks
MSR Germany IECEx, ATEX, SIL2 Butyl Acetate Gas Detector
Product Brochure
Minimum Order Quantity | 1 Piece |
Display Type | Digital, Analog |
Brand | MSR Germany |
Weight | 1.2 Kg |
Model Name/Number | Butyl Acetate Gas Detecttor |
Power | 24VDC |
Material | Aluminium di cast |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
Additional Information:
- Delivery Time: 2-8 weeks
MSR Germany IECEx, ATEX, SIL2 Hexane Gas Detector
Product Brochure
Minimum Order Quantity | 1 Piece |
Display Type | Digital, Analog |
Brand | MSR Germany |
Weight | 1.2 Kg |
Model Name/Number | Hexane Gas Detector |
Power | 24VDC |
Material | Aluminium di cast |
Accuracy | 1% |
Measurement Range | 0-100% LEL |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4 20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
- PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4 20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter,
Additional Information:
- Delivery Time: 2-8 weeks