Call 08048407375 84% Response Rate

Send Email

Flammable Combustible Gas Leak Detector

Providing you the best range of msr germany iecex, atex, sil2 toluene gas sensor, msr germany iecex, atex, sil2 methyl acetate gas sensor, msr germany iecex, atex, sil2 octane gas sensor, msr germany iecex, atex, sil2 ethyl acetate gas detector, msr germany iecex, atex, sil2 ethyl alcohol gas detector and toluene gas detector and monitor (c7h8) with effective & timely delivery.
MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor

MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor

Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Product Details:
Operating Temperature-20-50
Operating Humidity95%
Expected Operating Life3-5 years
Measuring Range0-100% LEL
Response Time10 second
Display TypeAnalog, Digital
BrandMSR Germany
Weight1.2 Kg
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 Methyl Acetate Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Methyl Acetate Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Methyl Acetate Gas Sensor

MSR Germany IECEx, ATEX, SIL2 Methyl Acetate Gas Sensor

Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Product Details:
Gas TypeCombustible Gas
Sensor TypeLPG
Usage/ApplicationGas Detection
Voltage24vdc
Weight1.2 kg
Display TypeAnalog, Digital
BrandMSR Germany
Model Name/NumberMethyl Acetate Gas Sensor
Power24VDC
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 Octane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Octane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Octane Gas Sensor

MSR Germany IECEx, ATEX, SIL2 Octane Gas Sensor

Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Product Details:
Display TypeDigital, Analog
BrandMSR Germany
Weight1.2 Kg
Model Name/NumberOctane Gas Sensor
Power24VDC
MaterialAluminium di cast
Accuracy1%
Measurement Range0-100% LEL
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 Ethyl Acetate Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Ethyl Acetate Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Ethyl Acetate Gas Detector

MSR Germany IECEx, ATEX, SIL2 Ethyl Acetate Gas Detector

Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Product Details:
Display TypeAnalog, Digital
BrandMSR Germany
Model Name/NumberEthyl Acetate Gas Detector
Weight1.2 Kg
Power24VDC
MaterialAluminium di cast
Accuracy1%
Measurement Range0-100% LEL
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4 20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
  • PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4 20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, 



Additional Information:

  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 Ethyl Alcohol Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Ethyl Alcohol Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Ethyl Alcohol Gas Detector

MSR Germany IECEx, ATEX, SIL2 Ethyl Alcohol Gas Detector

Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Product Details:
Display TypeAnalog, Digital
BrandMSR Germany
Model Name/NumberEthyl Alcohol Gas Detector
Weight1.2 Kg
Power24VDC
MaterialAluminium di cast
Accuracy1%
Measurement Range0-100% LEL
  • PX2 1 series with Ex db protection for Zone 1 and 2
  • PX2 2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4 20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
  • PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4 20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please 



Additional Information:

  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)
  • Toluene Gas Detector and Monitor (C7H8)

Toluene Gas Detector and Monitor (C7H8)

Price on Request

Product Brochure

Product Details:
Display TypeAnalog
BrandMSR Electronics
Model Name/NumberPX2-X-XXXX-X-X
Weight1.5 Kg
Power24VDC
MaterialAluminium die-casting or SS
Accuracy+/- 1% LEL
Measurement Range% LEL
Battery LifeNA
Status IndicationYes
Voltage24VDC
Warranty1 year
Signal Output4-20mA
ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world class cutting edge Toluene Gas Detector and Monitor (C7H8)

We are is involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.

FEATURES:

• ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection• Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay• For zone 1 (and also suitable for zone 2) Type “Ex db” with flame-proof enclosure• For zone 2: Type “Ex nA” with flame-proof enclosure• Continuous monitoring• Microprocessor with 12-bit converter resolution• Self-monitoring system• Easy calibration• Calibration service by exchanging the sensor head• Proportional 4–20 mA output• Serial interface to the control centre• Reverse polarity protection• Overload protection• LCD with status LEDs (optional)• Alarm and fault signal relay (optional)

Application:

• Coal mines, underground mines• Oil & gas, refinery• Fertilizer industry• Landfill gases• Sewage treatment plants (STP), effluent treatment facility• Cryogenic application• Chemical, petrochemical industry• Food processing industry• Furnace, burner application• Gas reticulation system

 
#TolueneDetector #Toluene Monitor #C7H8Detector #C7H8Monitor#FlammableLiquid#ExplosiveGas#FlammableGas#SolventMonitoring#ATEX#SIL2#IECEx #PESO #CCOE #DGMS #CMRI#Intrinsicallysafe#ExplosionProof#FlameProof#ZONE1#ZONE2#IECExCertified#ATEXCertified#SIL2Certified#HARTProtocol#ATEXGasDetector#ExplosionProof#ExplosiveGas#FlameproofGasDetector#FlameproofGasSensor#FlammableGas#Gasdetector#Gassensor#LEL#VOL#Detector#SIL2#Zone1#Zone2#Accessories #Adapter#Calibration #CalibrationGas#CellarAlarm #DigitalBusSensors #EnvironmentalMonitoring #FlameDetector#Fumigation #FumigationProducts#GasAlarm #GasControllers #GasDetectorTubes #GasTransmitters#GasSensorTransmitters#HandPumpsAccessories#HandTool#HazardousAre #IndoorAirQuality #MAPAnalysers #PolyGard2 #PolyXeta2 #Standalone #μGard2MC2Series#JunctionBO #JunctionBOXCopperFree#JunctionBoxMarineGrade#MarineGradeEnlosure#StainlessSteelEclocsure#StainlessSteelHousing#12BitConverterResolution#ExnA#Exdb#ElectricalExprotected#MetrologicalTesting#RS485#HART#Relay#LED#LCD#Continuousmonitoring#SelfMonitoringSystem#Easycalibration#Calibrationservice#exchanging#sensorhead#PlugPlay#4to20mAoutput#SerialInterface#ReversePolarityProtection#OverloadProtection#LCDDisplay#StatusLEDs #AlarmRelay#FaultSignalRelay
Get Best QuoteRequest Callback
Flameproof Petrol Diesel Vapours Sensor Transmitter
  • Flameproof Petrol Diesel Vapours Sensor Transmitter
  • Flameproof Petrol Diesel Vapours Sensor Transmitter

Flameproof Petrol Diesel Vapours Sensor Transmitter

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Display TypeDigital, Analog
Model Name/NumberPetrol Diesel Detector
Weight1.2 Kg
BrandMSR Germany
Measurement Range0-100% LEL
Power24VDC
MaterialAluminium
Accuracy1%

ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world-class cutting edge Flameproof Petrol Vapours Gas Detector Transmitter and Monitor.

We are  involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.

Description:

Ex-proof Petrol Vapours Sensor Transmitter and Monitor is a highly robust, industrial grade, flameproof, or explosion-proof gas detector for Flammable Petrol/Diesel Vapours detection in % LEL monitoring & Control Systems.

The detector is used for online, continuous monitoring of the  Flammable Gases in ambient air or duct or pipeline. It is ATEX, IECEx certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.

With Benefits:

  • ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  • Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
  • For zone 1 (and also suitable for zone 2) Type Ex db with flame-proof enclosure
  • For zone 2: Type Ex nA with flame-proof enclosure
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  • Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4 20 mA output
  • Serial interface to the control centre
  • Reverse polarity protection
  • Overload protection
  • LCD with status LEDs (optional)
  • Alarm and fault signal relay (optional)

 

Our Industries:
Our customers come from various industries like oil/gas, chemical, manufacturing, petrochemical, pharmaceutical, building, mining, nuclear, steel, defense, power, water, wastewater, mining, cement, dairy, automobile, etc. 



Additional Information:

  • Production Capacity: 100
  • Delivery Time: 2 to 8 weeks
Get Best QuoteRequest Callback
IECEx, ATEX, SIL2 Butadiene Gas Detector

IECEx, ATEX, SIL2 Butadiene Gas Detector

Price on Request

Product Brochure

Product Details:
BrandMSR Germany
Model Name/NumberButadiene Sensor
Display TypeDigital, Analog
Weight1.2 Kg
MaterialAluminium di cate
Measurement Range0-100%
Accuracy1%
Power24VDC
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Production Capacity: 100
  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany n-Heptane Gas Sensor
  • MSR Germany n-Heptane Gas Sensor
  • MSR Germany n-Heptane Gas Sensor

MSR Germany n-Heptane Gas Sensor

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Operating Temperature-20-50
Operating Humidity95%
Expected Operating Life3-5 years
Measuring Range0-100% LEL
Response Time10 second
Display TypeDigital, Analog
Model Name/Numbern-Heptane Gas Sensor
Weight1.2 Kg
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Production Capacity: 100
  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor

MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Display TypeAnalog, Digital
BrandMSR Germany
Model Name/NumberPropane Gas Leak Detection
Weight1.2 Kg
Power24VDC
MaterialAluminium di caste
Measurement Range0-100% LEL
Accuracy1%
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor

MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Display TypeAnalog, Digital
BrandMSR Germany
Weight1.2 Kg
Model Name/NumberPropane Gas Leak Detection
Power24VDC
MaterialAluminium di caste
Accuracy1%
Measurement Range0-5000 ppm
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 n- Pentane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 n- Pentane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 n- Pentane Gas Sensor

MSR Germany IECEx, ATEX, SIL2 n- Pentane Gas Sensor

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Display TypeAnalog, Digital
Model Name/Numbern- Pentane Gas Sensor
Weight1.2 Kg
BrandMSR Germany
Measurement Range0-100% LEL
Power24VDC
MaterialAluminium di cast
Accuracy1%
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Production Capacity: 100
  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 Cyclopentane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Cyclopentane Gas Sensor
  • MSR Germany IECEx, ATEX, SIL2 Cyclopentane Gas Sensor

MSR Germany IECEx, ATEX, SIL2 Cyclopentane Gas Sensor

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Operating Temperature-20-50
Operating Humidity95%
Expected Operating Life3-5 years
Measuring Range0-100% LEL
Response Time10 second
Display TypeAnalog, Digital
Model Name/NumberCyclopentane Gas Sensor
Weight1.2 Kg
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 Methyl Ethyl Ketone Gas Sensor

MSR Germany IECEx, ATEX, SIL2 Methyl Ethyl Ketone Gas Sensor

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Gas TypeCombustible Gas
BrandMSR Germany
Model Name/NumberMethyl Ethyl Ketone Gas Sensor
Sensor TypeMethyl Ethyl Ketone Gas Sensor
Usage/ApplicationGas Detection
Voltage24vdc
Weight1.2 kg
Display TypeAnalog
Power24VDC
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 Butyl Acetate Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Butyl Acetate Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Butyl Acetate Gas Detector

MSR Germany IECEx, ATEX, SIL2 Butyl Acetate Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Display TypeDigital, Analog
BrandMSR Germany
Weight1.2 Kg
Model Name/NumberButyl Acetate Gas Detecttor
Power24VDC
MaterialAluminium di cast
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 Hydrogen Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Hydrogen Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Hydrogen Gas Detector

MSR Germany IECEx, ATEX, SIL2 Hydrogen Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Display TypeAnalog, Digital
Measurement Range0-100 % LEL
BrandMSR Germany
Model Name/NumberFlamepoof Hydrogen Gas Detector
Power Source24vdc
Driven TypeContinuous Detection
ColorGrey Aluminium
MaterialAluminium Di cast
Voltage24vdc
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4 20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
  • PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4 20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, 



Additional Information:

  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 Benzene Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Benzene Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Benzene Gas Detector

MSR Germany IECEx, ATEX, SIL2 Benzene Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Display TypeAnalog, Digital
Model Name/NumberBenzene Gas Detector
Weight1.2 Kg
BrandMSR Germany
Measurement Range0-100% LEL
Power24VDC
MaterialAluminium di cast
Accuracy1%
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4 20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
  • PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4 20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, 



Additional Information:

  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 Ethane Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Ethane Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Ethane Gas Detector

MSR Germany IECEx, ATEX, SIL2 Ethane Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Display TypeDigital, Analog
Model Name/NumberEthane Gas Detector
Weight1.2 Kg
BrandMSR Germany
Measurement Range0-100% LEL
Power24VDC
MaterialAluminium di cast
Accuracy1%
  • PX2 1 series with Ex db protection for Zone 1 and 2
  • PX2 2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4 20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
  • PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4 20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please 



Additional Information:

  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
Ammonia Gas Sensor Transmitter
  • Ammonia Gas Sensor Transmitter
  • Ammonia Gas Sensor Transmitter
  • Ammonia Gas Sensor Transmitter
  • Ammonia Gas Sensor Transmitter
  • Ammonia Gas Sensor Transmitter
  • Ammonia Gas Sensor Transmitter
  • Ammonia Gas Sensor Transmitter

Ammonia Gas Sensor Transmitter

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity10 Piece
Operating Temperature-30 DegreeC to +60 DegreeC (-22 DegreeF to 140 DegreeF)
Gas TypeCombustible Gas
BrandMSR Germany
Operating Humidity5-95 % RH not condensing
Expected Operating LifeNA
Model Name/NumberMC2-X-P3408-A-X-X
Sensor TypeCatalytic Pellistor
Measuring Range0-100%LEL
Usage/ApplicationIndustrial
Voltage24VDC
Weight200gms
Display TypeOptional

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect NH3 Flammable/Combustible gas.

The MC2-X-P3408-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catalytic Pellistor Bead Sensor NH3 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Item Code: MC2-X-P3408-A-X-X
  • Production Capacity: 1000
  • Delivery Time: Ex-Stock or 4-6 Weeks
Get Best QuoteRequest Callback
MSR Germany Ex-Proof Nonane Sensor Transmitter
  • MSR Germany Ex-Proof Nonane Sensor Transmitter
  • MSR Germany Ex-Proof Nonane Sensor Transmitter

MSR Germany Ex-Proof Nonane Sensor Transmitter

Price on Request

Product Details:
Minimum Order Quantity1 Piece
Display TypeDigital, Analog
Output Signal4-20mA
Model Name/NumberNonane Gas Detector
Weight1.2 Kg
BrandMSR Germany

ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world-class cutting edge Flameproof Nonane Gas Detector Transmitter and Monitor.

We are  involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.

Description:

Ex-proof Nonane (C9H20) Gas Detector Transmitter and Monitor is a highly robust, industrial grade, flameproof, or explosion-proof gas detector for Flameproof C9H20 gas or Nonane detection in % LEL monitoring & Control Systems.

The detector is used for online, continuous monitoring of the Nonane Combustible Gases in ambient air or duct or pipeline. It is ATEX, IECEx certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.

With Benefits:

  • ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  • Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
  • For zone 1 (and also suitable for zone 2) Type Ex db with flame-proof enclosure
  • For zone 2: Type Ex nA with flame-proof enclosure
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  • Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4 20 mA output
  • Serial interface to the control centre
  • Reverse polarity protection
  • Overload protection
  • LCD with status LEDs (optional)
  • Alarm and fault signal relay (optional)

 

Our Industries:
Our customers come from various industries like oil/gas, chemical, manufacturing, petrochemical, pharmaceutical, building, mining, nuclear, steel, defense, power, water, wastewater, mining, cement, dairy, automobile, etc. 



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 2-8weeks
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector

MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector

Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Product Details:
Display TypeAnalog, Digital
BrandMSR Germany
Model Name/NumberMethanol Gas Detector
Weight1.2 Kg
Power24VDC
MaterialAluminium di cast
Accuracy1%
Measurement Range0-100% LEL
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Production Capacity: 100
  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany Butyl Acetate Gas Detector
  • MSR Germany Butyl Acetate Gas Detector
  • MSR Germany Butyl Acetate Gas Detector

MSR Germany Butyl Acetate Gas Detector

Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity+5 DegreeC to +30 DegreeC
Measuring Range0-100% LEL
Response Time< 15 sec.
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital, Optional
BrandMSR Germany
Model Name/NumberMC2-X-P3448-A-X-X
Weight200gms
Power24VDC
Usage/ApplicationIndustrial
Operating Voltage24VDC
MaterialPolycarbonate Enclosure
Measurement Range0-100%LEL
Accuracy1% LEL
ColorGrey
Shell MaterialPolycarbonate
Signal OutputAnalog 4-20mA
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C6H12O2 Combustible gas.

The MC2-X-E1110-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catalytic Pellistor C6H12O2 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Item Code: MC2-X-P3448-A-X-X
  • Production Capacity: 1000
  • Delivery Time: Ex-Stock or 4-6 weeks
Get Best QuoteRequest Callback
MSR Germany Cyclohexane Gas Detector
  • MSR Germany Cyclohexane Gas Detector
  • MSR Germany Cyclohexane Gas Detector

MSR Germany Cyclohexane Gas Detector

Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Product Brochure

Product Details:
BrandMSR Germany
Model Name/NumberMC2-X-P3415-A-X-X
Usage/ApplicationIndustrial
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Storage Temperature+5 DegreeC to +30 DegreeC
Sensor TypeCatalytic Pellistor
Voltage24VDC
Weight200gms
ColorGrey
MaterialPoycarbonate Enclosure
Response Time< 15 sec.
Accuracy1% LEL
Display TypeDigital, Optional
Power24VDC
Operating Voltage24VDC
Measurement Range0-100%LEL
Digital OutputNO
Humidity Range5-95 % RH not condensing
Mounting TypeDepending On Gas Type
Signal OutputAnalog 4-20mA
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C6H12 Combustible gas.

The MC2-X-P3415-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Cataylitic Pellistor C6H12  sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:

      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: Ex Stock or 4-6 Weeks
Get Best QuoteRequest Callback
MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector
  • MSR Germany Butadiene Gas Detector

MSR Germany Butadiene Gas Detector

Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Product Brochure

Product Details:
Display TypeOptional, Digital
BrandMSR Gerany
Weight200gms
Model Name/NumberMC2-X-P3494-A-X-X
Power24VDC
MaterialPolycarbonate Enclosure
Accuracy1% LEL
Measurement Range0-100% LEL
ColorGrey
Humidity Range5-95 % RH not condensing
Mounting TypeDepending On Gas Type
Signal Output4-20mA
Sensor TypeCatalytic Pellistor
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C4H6 Combustible/Flammable gas.

The MC2-X-E1110-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catlytic Pellistor C4H6 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
Get Best QuoteRequest Callback
MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector
  • MSR Germany Benzene Gas Detector

MSR Germany Benzene Gas Detector

Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Product Details:
Display TypeDigital
BrandMSR Germany
Model Name/NumberMC2-X-P3430-A-X-X
Weight200gmd
Power24VDC
MaterialPolycarbonate
Accuracy1% LEL
Measurement Range0-100%LEL
Battery LifeNA
ColorGrey
Humidity Range5-95 % RH not condensing
Mounting TypeDepending on Gas Type
Shell MaterialPolycarbonate
Voltage24VDC

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C6H6 Flammable/Combustible gas.

The MC2-X-P3430-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical C6H6 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe - Gas Detectors and Alarm Systems



Additional Information:

  • Item Code: MC2-X-P3430-A-X-X
  • Production Capacity: 1000
  • Delivery Time: Ex-Stock or 4-6 weeks
Get Best QuoteRequest Callback
MSR Germany Ethyl acetate Gas Detector
  • MSR Germany Ethyl acetate Gas Detector
  • MSR Germany Ethyl acetate Gas Detector

MSR Germany Ethyl acetate Gas Detector

Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec.
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital, Optional
BrandMSR Germany
Weight200gms
Model Name/NumberMC2-X-P3427-A-X
Power24VDC
Usage/ApplicationIndustrial
Operating Voltage24VDC
MaterialPolycarbonate Enclosure
Measurement Range0-100% LEL
Accuracy1% LEL
ColorGrey
Humidity Range5-95 % RH not condensing
Mounting TypeDepending on Gas Type
Voltage24VDC
Signal OutputAnalog 4-20mA
I Deal InNew Only

μGard 2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C4H8O2 Combustible gas.

The MC2-X-P3427-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C4H8O2 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35 degreeC
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
       EN 50271
       EN 50545
       EN 61010-1
       ANSI/UL 61010 1
       CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe - Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: Ex Stock or 4-6 Weeks
Get Best QuoteRequest Callback
MSR Germany Ethyl Alcohol Gas Detector
  • MSR Germany Ethyl Alcohol Gas Detector
  • MSR Germany Ethyl Alcohol Gas Detector

MSR Germany Ethyl Alcohol Gas Detector

Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Product Brochure

Product Details:
Gas TypeCombustible Gas
Usage/ApplicationIndustrial
Display TypeDigital
BrandMSR Germany
Weight200gms
Model Name/NumberMC2-X-P3425-A-X-X
Power24VDC
MaterialPolycarbonate Enclosure
Humidity5-95 % RH not condensing
Response Time< 15 sec. (CH4)
Accuracy1% LEL
Measurement Range0-100% LEL
Humidity Range5-95 % RH not condensing
Mounting TypeDepending on Gas
Voltage24VDC
Gases MeasuredEthyl alcohol,C2H5OH
I Deal InNew Only
Sensing ElementCatalytic Pellistor
Place Of OriginGermany

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C2H5OH Combustible gas.

The MC2-X-P3425-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C2H5OH sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe - Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: Ex stock or 4-6 Weeks
Get Best QuoteRequest Callback
MSR Germany Methyl Ethyl Ketone Gas Detector
  • MSR Germany Methyl Ethyl Ketone Gas Detector
  • MSR Germany Methyl Ethyl Ketone Gas Detector

MSR Germany Methyl Ethyl Ketone Gas Detector

Product Price: Rs 1 / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
BrandMSR Germany
Model Name/NumberMC2-X-P3458-A-X-X
Usage/ApplicationIndustrial
ColorGrey
Measurement Range0-100% LEL
I Deal InNew Only
Signal OutputAnalog 4-20mA

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C4H8O Combustible gas.

The MC2-X-P3458-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C4H8O sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 



Additional Information:

  • Production Capacity: 1000
Get Best QuoteRequest Callback
MSR Germany Iso/n-Butane Gas Detector
  • MSR Germany Iso/n-Butane Gas Detector
  • MSR Germany Iso/n-Butane Gas Detector

MSR Germany Iso/n-Butane Gas Detector

Product Price: Rs 40,000 / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Product Brochure

Product Details:
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-P3460-A-X-X
Weight200gms

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C4H10 Combustible gas.

The MC2-X-P3460-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C4H10 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 

 

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 4-6 weeks
Get Best QuoteRequest Callback
MSR Germany Isobutyl Alcohol Gas Detector
  • MSR Germany Isobutyl Alcohol Gas Detector
  • MSR Germany Isobutyl Alcohol Gas Detector

MSR Germany Isobutyl Alcohol Gas Detector

Product Price: Rs 45,000 / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Product Brochure

Product Details:
Display TypeDigital
BrandMSR Germany
Model Name/NumberMC2-X-P3468-A-X-X
Weight200gms
Power24VDC
MaterialPolycarbonate Enclosure
Accuracy1% LEL
Measurement Range0-100% LEL
ColorGrey
Humidity Range5-95 % RH not condensing
Mounting TypeDepending on Gas

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C4H10O Combustible gas.

The MC2-X-P3468-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catalytic Pellistor C4H10O sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 Acetone Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Acetone Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Acetone Gas Detector

MSR Germany IECEx, ATEX, SIL2 Acetone Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Gas TypeCombustible Gas
Usage/ApplicationGas Detection
Display TypeAnalog, Digital
Model Name/NumberAcetone Gas Detector
Weight1.2 Kg
BrandMSR Germany
Measurement Range0-100% LEL
Power24VDC
MaterialAluminium di caste
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 Hexane Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Hexane Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Hexane Gas Detector

MSR Germany IECEx, ATEX, SIL2 Hexane Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Display TypeAnalog, Digital
BrandMSR Germany
Weight1.2 Kg
Model Name/NumberHexane Gas Detector
Power24VDC
MaterialAluminium di cast
Measurement Range0-100% LEL
Accuracy1%
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4 20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
  • PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4 20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, 



Additional Information:

  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 Cyclohexane  Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Cyclohexane  Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 Cyclohexane  Gas Detector

MSR Germany IECEx, ATEX, SIL2 Cyclohexane Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Display TypeAnalog, Digital
BrandMSR Germany
Model Name/NumberCyclohexane Gas Detector
Weight1.2 Kg
Power24VDC
MaterialAluminium di cast
Accuracy1%
Measurement Range0-100% LEL
  • PX2 1 series with Ex db protection for Zone 1 and 2
  • PX2 2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4-20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
  • PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4 20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts 



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 LPG Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 LPG Gas Detector
  • MSR Germany IECEx, ATEX, SIL2 LPG Gas Detector

MSR Germany IECEx, ATEX, SIL2 LPG Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
Display TypeAnalog, Digital
BrandMSR Germany
Model Name/NumberFlameproof LPG Gas Detector
Weight1.2 Kg
Power24VDC
MaterialAluminium di cast
Measurement Range0-100% LEL
Accuracy1%
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4-20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
  • PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4-20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts 



Additional Information:

  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback
MSR Germany Cyclopentane Gas Detector
  • MSR Germany Cyclopentane Gas Detector
  • MSR Germany Cyclopentane Gas Detector

MSR Germany Cyclopentane Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity10 Piece
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec.
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeOptional, Digital
Model Name/NumberMC2-X-X-P3472-A-X
Weight200gms
Measurement Range0-100% LEL
Power24VDC
Usage/ApplicationIndustrial
Operating Voltage24VDC
BrandMSR Germany
ColorGrey
Accuracy1% LEL
Humidity Range5-95 % RH not condensing
MaterialPolycarbonate
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C5H10 Combustible gas.

The MC2-X-P3472-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catalytic Pellisytor C5H10 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
Get Best QuoteRequest Callback
MSR Germany Ethane Gas Detector
  • MSR Germany Ethane Gas Detector
  • MSR Germany Ethane Gas Detector

MSR Germany Ethane Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity10 Piece
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec.
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeOptional, Digital
Model Name/NumberMC2-X-P3420-A-X-X
Weight200gms
BrandMSR Germany
Measurement Range0-100% LEL
Power24VDC
Usage/ApplicationIndustrial
Operating Voltage24VDC
MaterialPolycarbonate Enclosure
Accuracy1% LEL
ColorGrey
Humidity Range5-95 % RH not condensing
Mounting TypeDepending on Gas Type
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C2H6 Combustible gas.

The MC2-X-P3420-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C2H6 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
Get Best QuoteRequest Callback
MSR Germany Ethylene Gas Detector
  • MSR Germany Ethylene Gas Detector
  • MSR Germany Ethylene Gas Detector

MSR Germany Ethylene Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity10 Piece
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-X-P3410-A-X
Weight200gms
BrandMSR Germany

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C2H4 Combustible gas.

The MC2-X-P3410-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C2H4 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
Get Best QuoteRequest Callback
MSR Germany Isopropyl Alcohol Gas Detector
  • MSR Germany Isopropyl Alcohol Gas Detector
  • MSR Germany Isopropyl Alcohol Gas Detector

MSR Germany Isopropyl Alcohol Gas Detector

Price on Request

Product Brochure

Product Details:
Display TypeDigital
BrandMSR Germany
Weight200gms
Model Name/NumberMC2-X-P3482-A-X-X
Power24VDC
MaterialPolycarbonate Enclosure
Measurement Range0-100% LEL
Accuracy1% LEL
ColorGrey
Humidity Range5-95 % RH not condensing
Mounting TypeDepending on Gas
Signal OutputAnalog 4-20mA
Sensor TypeCatalytic Pellistor
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C3H8O Combustible gas.

The MC2-X-P3482-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C3H8O sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 100
Get Best QuoteRequest Callback
MSR Germany Iso/n-Pentane Gas Detector
  • MSR Germany Iso/n-Pentane Gas Detector
  • MSR Germany Iso/n-Pentane Gas Detector

MSR Germany Iso/n-Pentane Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity10 Piece
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-P3475-A-X-X
Weight200gms
BrandMSR Germany
Measurement Range0-100% LEL
Power24VDC
MaterialPolycarbonate Enclosure

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C5H12 Combustible gas.

The MC2-X-P3475-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C5H12  sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 

Be sure, Be safe – Gas Detectors and Alarm Systems



Additional Information:

  • Production Capacity: 1000
Get Best QuoteRequest Callback
Msr Germany Methane Gas Detector
  • Msr Germany Methane Gas Detector
  • Msr Germany Methane Gas Detector

Msr Germany Methane Gas Detector

Price on Request

Product Brochure

Product Details:
BrandMSR Germany
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Storage Temperature+5 DegreeC to +30 DegreeC
Measuring Range0-100% LEL
Weight200gms
ColorGrey
Response Time< 15 sec. (CH4)
Display TypeDigital
Sensor TypeCatalytic Pellistor
Usage/ApplicationIndustrial
Model Name/NumberMC2-X-P3400-A-X-X
Power24VDC
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Methane Combustible gas.

The MC2-X-P3400-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the CH4 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 



Additional Information:

  • Production Capacity: 1000
Get Best QuoteRequest Callback
MSR Germany Methanol Gas Detector
  • MSR Germany Methanol Gas Detector
  • MSR Germany Methanol Gas Detector

MSR Germany Methanol Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity10 Piece
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-P3450-A-X-X
Weight200gms
Measurement Range0-100% LEL
Power24VDC
Usage/ApplicationIndustrial
BrandMSR Germany
ColorGrey
Mounting TypeDepending on Gas Type
I Deal InNew Only
Sensor TypeCatalytic Pellistor

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect CH3OH Combustible gas.

The MC2-X-P3450-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the CH3OH module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 



Additional Information:

  • Production Capacity: 1000
Get Best QuoteRequest Callback
MSR Germany Methyl Acetate Gas Detector
  • MSR Germany Methyl Acetate Gas Detector
  • MSR Germany Methyl Acetate Gas Detector

MSR Germany Methyl Acetate Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity10 Piece
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-P3473-A-X-X
BrandMSR Germany
Measurement Range0-100% LEL
Usage/ApplicationIndustrial
MaterialPolycarbonate Enclosure
Operating Voltage24VDC
ColorGrey
Mounting TypeDepending on Gas
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C3H6O2 Combustible gas.

The MC2-X-P3473-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C3H6O2 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 378
      o EN 45544
      o EN 50104 (for O2)
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 

 



Additional Information:

  • Production Capacity: 1000
Get Best QuoteRequest Callback
MSR Germany n-Heptane Gas Detector
  • MSR Germany n-Heptane Gas Detector
  • MSR Germany n-Heptane Gas Detector

MSR Germany n-Heptane Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity10 Piece
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-P3491-A-X-X
Weight200gms
BrandMSR Germany
Usage/ApplicationIndustrial
Operating Voltage24VDC
MaterialPolycarbonate Enclosure
Sensor TypeCatalytic Pellistor
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C7H16 Combustible gas.

The MC2-X-P3491-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C7H16 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 378
      o EN 45544
      o EN 50104 (for O2)
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 



Additional Information:

  • Production Capacity: 1000
Get Best QuoteRequest Callback
MSR Germany n-Hexane Gas Detector
  • MSR Germany n-Hexane Gas Detector
  • MSR Germany n-Hexane Gas Detector

MSR Germany n-Hexane Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity10 Piece
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-P3435-A--X-X
Weight200gms
BrandMSR Germany
Usage/ApplicationIndustrial
MaterialPolycarbonate Enclosure
Operating Voltage24VDC
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C6H14 Combustible gas.

The MC2-X-P3435-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C6H14  sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 



Additional Information:

  • Production Capacity: 1000
Get Best QuoteRequest Callback
MSR Germany Nonane Gas Detector
  • MSR Germany Nonane Gas Detector
  • MSR Germany Nonane Gas Detector

MSR Germany Nonane Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity10 Piece
Gas TypeCombustible Gas
BrandMSR Germany
Model Name/NumberMC2-X-P3495-A-X-X
Sensor TypeCatalytic Pellistor
Usage/ApplicationIndustrial
Voltage24VDC
Weight200gms
Display TypeDigital
Measurement Range0-100% LEL
ColorGrey
MaterialPolycarbonate Enclosure

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C9H20 Combustible gas.

Tiche MC2-X-P3495-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C9H20 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.

 



Additional Information:

  • Production Capacity: 1000
Get Best QuoteRequest Callback
MSR Germany Octane Gas Detector
  • MSR Germany Octane Gas Detector
  • MSR Germany Octane Gas Detector

MSR Germany Octane Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity10 Piece
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-P3470-A-X-X
Weight200gms
Usage/ApplicationIndustrial
BrandMSR Germany
ColorGrey

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C8H18 Combustible gas.

The MC2-X-P3470-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C8H18 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 



Additional Information:

  • Production Capacity: 1000
Get Best QuoteRequest Callback
MSR Germany Petrol Vapours Detector
  • MSR Germany Petrol Vapours Detector
  • MSR Germany Petrol Vapours Detector

MSR Germany Petrol Vapours Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity10 Piece
Gas TypeCombustible Gas
Usage/ApplicationIndustrial
Display TypeDigital
Model Name/NumberMC2-X-P3460-A-X-X
Weight200gms
BrandMSR Germany
Measurement Range0-100% LEL
Power24VDC
MaterialPolycarbonate Enclosure
Humidity5-95 % RH not condensing
Response Time< 15 sec. (CH4)
ColorGrey
Mounting TypeDepending on Gas
Output CurrentAnalog 4-20mA
Sensor TypeCatalytic Pellistor
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Petrol Vapours.

The MC2-X-P3496-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Petrol Vapours sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 



Additional Information:

  • Production Capacity: 1000
Get Best QuoteRequest Callback
MSR Germany Propane Gas Detector
  • MSR Germany Propane Gas Detector
  • MSR Germany Propane Gas Detector

MSR Germany Propane Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity10 Piece
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Display TypeDigital
Model Name/NumberMC2-X-P3480-A-X-X
Weight200gms
BrandMSR Germany
Usage/ApplicationIndustrial
I Deal InNew Only

μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C3H8 Combustible gas.

The MC2-X-P3480-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C3H8 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 



Additional Information:

  • Production Capacity: 10000
Get Best QuoteRequest Callback
MSR Germany Toluene Gas Detector
  • MSR Germany Toluene Gas Detector
  • MSR Germany Toluene Gas Detector

MSR Germany Toluene Gas Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity10 Piece
Operating Temperature-30 DegreeC to +60 DegreeC
Operating Humidity5-95 % RH not condensing
Measuring Range0-100% LEL
Response Time< 15 sec. (CH4)
Storage Temperature+5 DegreeC to +30 DegreeC
Model Name/NumberMC2-X-P3490-A-X-X
Weight200gms
BrandMSR Germany
Usage/ApplicationIndustrial
MaterialPolycarbonate Enclosure
Operating Voltage24VDC
ColorGrey
Sensor TypeCatalytic Pellistor
I Deal InNew Only

UGard 2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C7H8 Combustible gas.

The MC2-X-P3490-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C7H8 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.

Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.

FEATURES

  • Digital measurement value processing incl. temperature compensation
  • Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Sensor life time: Refer the datasheet 
  • SIL2 Compliant development process
  • Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
  • 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
  • Reverse polarity protected, overload and short-circuit proof
  • Integrated heating down to -35°C
  • Optional:
    • Without housing
    • With housing Plastic: Type D, 94 x 65 x 57 mm
    • 4-20 mA output signal
    • 2-10 V output signal
    • With display for values and operation, 2x open collector for horn and warning lamp
    • Conformity to:
      o EN 50271
      o EN 50545
      o EN 61010-1
      o ANSI/UL 61010 1
      o CAN/CSA-C22.2 No. 61010-1
      • Duct mounting kit (accessory)

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.

 



Additional Information:

  • Production Capacity: 10000
Get Best QuoteRequest Callback
MSR Germany IECEx, ATEX, SIL2 Isopropyl Alcohol Gas Leak Detector

MSR Germany IECEx, ATEX, SIL2 Isopropyl Alcohol Gas Leak Detector

Price on Request

Product Brochure

Product Details:
Minimum Order Quantity1 Piece
BrandMSR Germany
Usage/ApplicationIsopropyl Alcohol Gas Leak Detection
Display TypeDigital, Analog
Weight1.2 Kg
Model Name/NumberIsopropyl Alcohol Gas Leak Detection
  • PX2-1 series with Ex db protection for Zone 1 and 2
  • PX2-2 series with Ex nA protection only for Zone 2

Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.

Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).

The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.

 

FEATURES:

  •  ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  •  Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  •  PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
  • PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
  • Enclosure: additional CSA certificate for Class I, Div. 1
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  •  Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD display with status LEDs (optional)
  •  Alarm and fault signal relay (optional)

Our Industries:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing
  • Chemical
  • Manufacturing
  • Petrochemical
  • Pharmaceutical
  • Building/Commercial Automation
  • Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.



Additional Information:

  • Delivery Time: 2-8 weeks
Get Best QuoteRequest Callback

EXPLORE MORE CATEGORIES

Looking For "Flammable Combustible Gas Leak Detector"?
Thank you Your Enquiry has been sent successfully.
© ALVI Automation India Private Limited. All Rights Reserved (Terms of Use)Developed and managed by IndiaMART InterMESH Ltd.