Ammonia Gas Sensor
Product Brochure
Measuring Range | 0-300 ppm |
Model No | MSR - ADT-03-3408 |
Usage | Industrial |
Working Temperature | -10deg C to +50deg C |
Detector Type | Portable Single Gas |
Resolution | +- 3 ppm |
Power Supply | 18 - 28 VDC ( Overload protected) |
Display Type | Digital |
Methane Gas Sensor Transmitter
Product Brochure
Measuring Range | 0-300 ppm |
Model No | MSR - MA-2-3400 |
Sensor Coverage Area | 700 m2 to 750 m2 |
Working Temperature | -10deg C to +50deg C |
Resolution | +- 3 ppm |
Ammonia Gas Sensor Transmitter
Product Brochure
Model No | MC2-X-S2125-A-0 |
Type | Gas Sensor |
Usage | Industrial |
Working Temperature | -10deg C to +50deg C |
Resolution | +- 3 ppm |
Power Supply | 24 VDC |
Usage/Application | cold storage,ammonia plant |
Gas Type | Ammonia |
Model Number | MSR |
Brand | MSR Germany |
Display Type | Analog,Digital |
Combustible Gas Sensor Transmitter Detector Analyzer
Frequency | 200~1000Hz(optional) |
Measuring Range | 0-100% LEL (lower explosive limit) |
Output Signal | 4-20mA, 0-10V |
Display Type | Digital |
- Gas Bank, Lpg Bottling Plant, Lpg Booster Station, Lpg Store, Pharmaceutical, Cylinder Store, Gems Processing, Heat Processing, Furnace, Engine Room, Testing Rooms, Automobile, Defence, Warship, Anniling Plant, Chemical Plants, Oil & Gas, Fire Safety, Kitchen, Refinery, Food Processing, Cement, Bearing, Machine Industry, Swimming Pool, Combustion Area, Bakery, Commerical, Hotels, Mines, Confined Space, Lpg Pipeline Etc.
Features:
- Reverse Polarity Protected
- Poisoning Protected
- Low Flashing Temperature For Longer Sensor
- Modular Architecture
- Manual Calibration
- Expected Life: 3 Years
- Low Response Time
Gas Type Available:
Combustible Gas Detector, Confined Space Gas Detector, Gas Detection System, Gas Detectors, Gas Analyzers, Exhaust Gas Analysers, Biogas Analyser, Stack Gas Analyser, Catalytic Gas Sensor, Combustible Gas Sensor, Gas Sensors, Hydrogen Gas Sensor, Methane Detector, Lpg Bottling Plants, Lpg Burners, Lpg Cylinder Plant, Lpg Fuel Tank, Lpg Gas Leakage Sensor, Gas Train, Lpg Gas Tanker, Lpg Station, Lpg Vaporizer, Natural Gas Alarm, Natural Gas Plants, Combustion Analyzer, Biogas Generation Plant, Biogas Generator, Biogas Power Generation Plant, Biomass Gasifier.
MSR Germany Combustible Gas Sensors
Product Brochure
Mounting Type | Ceiling |
Humidity Range | 95% |
Color | Grey |
Accuracy | 1% |
Material | Polycarbonate |
Temperature | 0-50 deg C |
Power Source | 24 VDC |
Display Type | Analog |
Measurement Range | 0-100% LEL |
Flameproof Petrol Diesel Vapours Sensor Transmitter
Product Brochure
Material | Aluminium |
Brand | MSR Germany |
Accuracy | 1% |
Power | 24VDC |
Weight | 1.2 Kg |
Display Type | Analog,Digital |
Model Name/Number | Petrol Diesel Detector |
Measurement Range | 0-100% LEL |
ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world-class cutting edge Flameproof Petrol Vapours Gas Detector Transmitter and Monitor.
We are involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.
Description:
Ex-proof Petrol Vapours Sensor Transmitter and Monitor is a highly robust, industrial grade, flameproof, or explosion-proof gas detector for Flammable Petrol/Diesel Vapours detection in % LEL monitoring & Control Systems.
The detector is used for online, continuous monitoring of the Flammable Gases in ambient air or duct or pipeline. It is ATEX, IECEx certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.
With Benefits:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- For zone 1 (and also suitable for zone 2) Type Ex db with flame-proof enclosure
- For zone 2: Type Ex nA with flame-proof enclosure
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4 20 mA output
- Serial interface to the control centre
- Reverse polarity protection
- Overload protection
- LCD with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
Our customers come from various industries like oil/gas, chemical, manufacturing, petrochemical, pharmaceutical, building, mining, nuclear, steel, defense, power, water, wastewater, mining, cement, dairy, automobile, etc.
MSR Germany IECEx, ATEX, SIL2 Isopropyl Alcohol Gas Leak Detector
Product Brochure
Minimum Order Quantity | 1 Piece |
Display Type | Digital,Analog |
Usage/Application | Isopropyl Alcohol Gas Leak Detection |
Weight | 1.2 Kg |
Model Name/Number | Isopropyl Alcohol Gas Leak Detection |
Brand | MSR Germany |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
MSR Germany IECEx, ATEX, SIL2 Benzene Gas Detector
Product Brochure
Minimum Order Quantity | 1 Piece |
Material | Aluminium di cast |
Brand | MSR Germany |
Accuracy | 1% |
Power | 24VDC |
Weight | 1.2 Kg |
Display Type | Analog,Digital |
Model Name/Number | Benzene Gas Detector |
Measurement Range | 0-100% LEL |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4 20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
- PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4 20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter,
MSR Germany IECEx, ATEX, SIL2 Hexane Gas Detector
Product Brochure
Minimum Order Quantity | 1 Piece |
Material | Aluminium di cast |
Brand | MSR Germany |
Accuracy | 1% |
Display Type | Analog,Digital |
Power | 24VDC |
Weight | 1.2 Kg |
Model Name/Number | Hexane Gas Detector |
Measurement Range | 0-100% LEL |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4 20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
- PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4 20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter,
MSR Germany IECEx, ATEX, SIL2 Ethyl Acetate Gas Detector
Product Brochure
Material | Aluminium di cast |
Brand | MSR Germany |
Accuracy | 1% |
Display Type | Digital,Analog |
Power | 24VDC |
Weight | 1.2 Kg |
Model Name/Number | Ethyl Acetate Gas Detector |
Measurement Range | 0-100% LEL |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4 20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
- PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4 20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter,
MSR Germany IECEx, ATEX, SIL2 Ethane Gas Detector
Product Brochure
Minimum Order Quantity | 1 Piece |
Material | Aluminium di cast |
Brand | MSR Germany |
Accuracy | 1% |
Power | 24VDC |
Weight | 1.2 Kg |
Display Type | Analog,Digital |
Model Name/Number | Ethane Gas Detector |
Measurement Range | 0-100% LEL |
- PX2 1 series with Ex db protection for Zone 1 and 2
- PX2 2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4 20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
- PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4 20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please
MSR Germany IECEx, ATEX, SIL2 Acetone Gas Detector
Product Brochure
Minimum Order Quantity | 1 Piece |
Material | Aluminium di caste |
Brand | MSR Germany |
Power | 24VDC |
Weight | 1.2 Kg |
Display Type | Analog,Digital |
Gas Type | Combustible Gas |
Model Name/Number | Acetone Gas Detector |
Usage/Application | Gas Detection |
Measurement Range | 0-100% LEL |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
MSR Germany IECEx, ATEX, SIL2 Butyl Acetate Gas Detector
Product Brochure
Minimum Order Quantity | 1 Piece |
Material | Aluminium di cast |
Brand | MSR Germany |
Display Type | Digital,Analog |
Power | 24VDC |
Weight | 1.2 Kg |
Model Name/Number | Butyl Acetate Gas Detecttor |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
MSR Germany Ex-Proof Nonane Sensor Transmitter
Minimum Order Quantity | 1 Piece |
Output Signal | 4-20mA |
Brand | MSR Germany |
Weight | 1.2 Kg |
Display Type | Digital,Analog |
Model Name/Number | Nonane Gas Detector |
ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world-class cutting edge Flameproof Nonane Gas Detector Transmitter and Monitor.
We are involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.
Description:
Ex-proof Nonane (C9H20) Gas Detector Transmitter and Monitor is a highly robust, industrial grade, flameproof, or explosion-proof gas detector for Flameproof C9H20 gas or Nonane detection in % LEL monitoring & Control Systems.
The detector is used for online, continuous monitoring of the Nonane Combustible Gases in ambient air or duct or pipeline. It is ATEX, IECEx certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.
With Benefits:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- For zone 1 (and also suitable for zone 2) Type Ex db with flame-proof enclosure
- For zone 2: Type Ex nA with flame-proof enclosure
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4 20 mA output
- Serial interface to the control centre
- Reverse polarity protection
- Overload protection
- LCD with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
Our customers come from various industries like oil/gas, chemical, manufacturing, petrochemical, pharmaceutical, building, mining, nuclear, steel, defense, power, water, wastewater, mining, cement, dairy, automobile, etc.
Toluene Gas Detector and Monitor (C7H8)
Product Brochure
Signal Output | 4-20mA |
Status Indication | Yes |
Material | Aluminium die-casting or SS |
Brand | MSR Electronics |
Accuracy | +/- 1% LEL |
Battery Life | NA |
Voltage | 24VDC |
Warranty | 1 year |
Power | 24VDC |
Display Type | Analog |
Weight | 1.5 Kg |
Model Name/Number | PX2-X-XXXX-X-X |
Measurement Range | % LEL |
We are is involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.
FEATURES:
• ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection• Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay• For zone 1 (and also suitable for zone 2) Type “Ex db” with flame-proof enclosure• For zone 2: Type “Ex nA” with flame-proof enclosure• Continuous monitoring• Microprocessor with 12-bit converter resolution• Self-monitoring system• Easy calibration• Calibration service by exchanging the sensor head• Proportional 4–20 mA output• Serial interface to the control centre• Reverse polarity protection• Overload protection• LCD with status LEDs (optional)• Alarm and fault signal relay (optional)
Application:
• Coal mines, underground mines• Oil & gas, refinery• Fertilizer industry• Landfill gases• Sewage treatment plants (STP), effluent treatment facility• Cryogenic application• Chemical, petrochemical industry• Food processing industry• Furnace, burner application• Gas reticulation system
#TolueneDetector #Toluene Monitor #C7H8Detector #C7H8Monitor#FlammableLiquid#ExplosiveGas#FlammableGas#SolventMonitoring#ATEX#SIL2#IECEx #PESO #CCOE #DGMS #CMRI#Intrinsicallysafe#ExplosionProof#FlameProof#ZONE1#ZONE2#IECExCertified#ATEXCertified#SIL2Certified#HARTProtocol#ATEXGasDetector#ExplosionProof#ExplosiveGas#FlameproofGasDetector#FlameproofGasSensor#FlammableGas#Gasdetector#Gassensor#LEL#VOL#Detector#SIL2#Zone1#Zone2#Accessories #Adapter#Calibration #CalibrationGas#CellarAlarm #DigitalBusSensors #EnvironmentalMonitoring #FlameDetector#Fumigation #FumigationProducts#GasAlarm #GasControllers #GasDetectorTubes #GasTransmitters#GasSensorTransmitters#HandPumpsAccessories#HandTool#HazardousAre #IndoorAirQuality #MAPAnalysers #PolyGard2 #PolyXeta2 #Standalone #μGard2MC2Series#JunctionBO #JunctionBOXCopperFree#JunctionBoxMarineGrade#MarineGradeEnlosure#StainlessSteelEclocsure#StainlessSteelHousing#12BitConverterResolution#ExnA#Exdb#ElectricalExprotected#MetrologicalTesting#RS485#HART#Relay#LED#LCD#Continuousmonitoring#SelfMonitoringSystem#Easycalibration#Calibrationservice#exchanging#sensorhead#PlugPlay#4to20mAoutput#SerialInterface#ReversePolarityProtection#OverloadProtection#LCDDisplay#StatusLEDs #AlarmRelay#FaultSignalRelay
IECEx, ATEX, SIL2 Butadiene Gas Detector
Product Brochure
Material | Aluminium di cate |
Brand | MSR Germany |
Accuracy | 1% |
Display Type | Digital,Analog |
Power | 24VDC |
Weight | 1.2 Kg |
Model Name/Number | Butadiene Sensor |
Measurement Range | 0-100% |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
Acetone Gas Detector
Product Brochure
Material | Polycarbonate or SS |
Brand | MSR |
Color | Grey |
Mounting Type | Depending o Gas Density |
Accuracy | 1% LEL |
Humidity Range | 5-95 % RH not condensing |
Display Type | Digital,Analog |
Power | 24 VDC |
Weight | 150 g |
Model Name/Number | MC2-X-P3485-A-X-X |
Measurement Range | 0-100% LEL or % Vol |
Gard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self control for the continuous monitoring of the ambient air to detect Acetone (C3H6O) Combustible/Flammable gas.
The MC2-XP3485 X X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catalytic Pellistor Bead (C3H6O) sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4 20 mA (or 2 10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
Digital measurement value processing incl. temperature compensationData / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
Low zero point drift
Sensor life time: Refer the datasheet
SIL2 Compliant development process
Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
4 20 mA (or 2 10V) analog output with selectable signal output for special mode, fault etc.
Reverse polarity protected, overload and short-circuit proof
Integrated heating down to 35COptional:Without housing
With housing Plastic: Type D, 94 x 65 x 57 mm
4 20 mA output signal
2 10 V output signal
With display for values and operation, 2x open collector for horn and warning lamp
Conformity to:
o EN 50271
o EN 50545:2017
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2 10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Should you have any questions or concerns regarding this matter, please
Be sure, Be safe Gas Detectors and Alarm Systems
MSR Germany IECEx, ATEX, SIL2 Octane Gas Sensor
Product Brochure
Material | Aluminium di cast |
Brand | MSR Germany |
Accuracy | 1% |
Display Type | Digital,Analog |
Power | 24VDC |
Weight | 1.2 Kg |
Model Name/Number | Octane Gas Sensor |
Measurement Range | 0-100% LEL |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
Ammonia Gas Detector
Product Brochure
Voltage | 24VAC/DC |
Termination | 3 |
Power Source | 24VDC/AC |
Material | poly carbonate |
Humidity | 95% Rh |
Tests | CE, UL |
Size | 23x24 mm |
Brand | MSR |
Color | Grey |
Indicators | 3 |
Number Of Buttons | 3 |
Resolution | 1 PPM |
Mounting | Ceiling |
Sensor Type | MC2 |
Usage/Application | Cold storage and gas cylinder area |
Product Type | MC2 |
Accuracy | 1 ppm |
Gas Type | Ammonia |
Response Time | 30 |
Power | 24VDC/AC |
Temperature | 50 |
Weight | 120 |
Display Type | Digital |
FEATURES
??? Digital measurement value processing
??? Internal function control with integrated hardware watchdog
??? Data / measured values in μC of the sensor unit, therefore simple exchangeuncalibrated <> calibrated
??? High accuracy, selectivity and reliability
??? Low zero point drift
??? Long sensor life time
???Hardware & software according to SIL2 compliant development process
??? Easy maintenance and calibration by exchange of the sensor unit or by comfortableon-site calibration
??? 4 – 20 mA (or 2 – 10 V) analog output with selectable signal output for special mode,fault etc.
???Reverse polarity protected, overload and short-circuit proof??? Housing for integration of the sensor unit
??? IP 65 version
??? Display (option)
??? Display with two open-collector outputs for horn (resettable) and warning lamp(option)
??? Conformity too EN 61508-1-3o EN 61010-1o ANSI/UL 61010 1o CAN/CSA-C22.2 No. 61010-1o EN 378o EN 45544-1
??? Duct mounting kit (accessory)
For more details please feel free to contact us
MSR Germany IECEx, ATEX, SIL2 Methyl Acetate Gas Sensor
Product Brochure
Brand | MSR Germany |
Sensor Type | LPG |
Weight | 1.2 kg |
Voltage | 24vdc |
Display Type | Digital,Analog |
Power | 24VDC |
Gas Type | Combustible Gas |
Model Name/Number | Methyl Acetate Gas Sensor |
Usage/Application | Gas Detection |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
MSR Germany IECEx, ATEX, SIL2 Methanol Gas Detector
Product Brochure
Material | Aluminium di cast |
Brand | MSR Germany |
Accuracy | 1% |
Display Type | Digital,Analog |
Power | 24VDC |
Weight | 1.2 Kg |
Model Name/Number | Methanol Gas Detector |
Measurement Range | 0-100% LEL |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
MSR Germany IECEx, ATEX, SIL2 Ethyl Alcohol Gas Detector
Product Brochure
Material | Aluminium di cast |
Brand | MSR Germany |
Accuracy | 1% |
Display Type | Digital,Analog |
Power | 24VDC |
Weight | 1.2 Kg |
Model Name/Number | Ethyl Alcohol Gas Detector |
Measurement Range | 0-100% LEL |
- PX2 1 series with Ex db protection for Zone 1 and 2
- PX2 2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4 20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
- PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4 20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please
MSR Germany IECEx, ATEX, SIL2 Cyclohexane Gas Detector
Product Brochure
Minimum Order Quantity | 1 Piece |
Material | Aluminium di cast |
Brand | MSR Germany |
Accuracy | 1% |
Display Type | Analog,Digital |
Power | 24VDC |
Weight | 1.2 Kg |
Model Name/Number | Cyclohexane Gas Detector |
Measurement Range | 0-100% LEL |
- PX2 1 series with Ex db protection for Zone 1 and 2
- PX2 2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4-20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
- PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4 20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts
MSR Germany IECEx, ATEX, SIL2 LPG Gas Detector
Product Brochure
Minimum Order Quantity | 1 Piece |
Material | Aluminium di cast |
Brand | MSR Germany |
Accuracy | 1% |
Display Type | Analog,Digital |
Power | 24VDC |
Weight | 1.2 Kg |
Model Name/Number | Flameproof LPG Gas Detector |
Measurement Range | 0-100% LEL |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4-20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4 20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type Ex db with flame-proof enclosure
- PX2-2 for zone 2: Type Ex nA with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4-20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts
MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
Product Brochure
Material | Aluminium di caste |
Brand | MSR Germany |
Accuracy | 1% |
Display Type | Digital,Analog |
Power | 24VDC |
Weight | 1.2 Kg |
Model Name/Number | Propane Gas Leak Detection |
Measurement Range | 0-100% LEL |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
MSR Germany IECEx, ATEX, SIL2 Propane Gas Sensor
Product Brochure
Material | Aluminium di caste |
Brand | MSR Germany |
Accuracy | 1% |
Display Type | Digital,Analog |
Power | 24VDC |
Weight | 1.2 Kg |
Model Name/Number | Propane Gas Leak Detection |
Measurement Range | 0-5000 ppm |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
Ammonia Gas Sensor Transmitter
Product Brochure
Display Type | Optional |
Model Name/Number | MC2-X-P3408-A-X-X |
Measuring Range | 0-100%LEL |
Expected Operating Life | NA |
Operating Temperature | -30 DegreeC to +60 DegreeC (-22 DegreeF to 140 DegreeF) |
Operating Humidity | 5-95 % RH not condensing |
Brand | MSR Germany |
Sensor Type | Catalytic Pellistor |
Weight | 200gms |
Voltage | 24VDC |
Gas Type | Combustible Gas |
Usage/Application | Industrial |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect NH3 Flammable/Combustible gas.
The MC2-X-P3408-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Catalytic Pellistor Bead Sensor NH3 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
MSR Germany IECEx, ATEX, SIL2 n- Pentane Gas Sensor
Product Brochure
Material | Aluminium di cast |
Brand | MSR Germany |
Accuracy | 1% |
Power | 24VDC |
Weight | 1.2 Kg |
Display Type | Analog,Digital |
Model Name/Number | n- Pentane Gas Sensor |
Measurement Range | 0-100% LEL |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
MSR Germany IECEx, ATEX, SIL2 Cyclopentane Gas Sensor
Product Brochure
Response Time | 10 second |
Measuring Range | 0-100% LEL |
Expected Operating Life | 3-5 years |
Operating Temperature | -20-50 |
Operating Humidity | 95% |
Weight | 1.2 Kg |
Display Type | Digital,Analog |
Model Name/Number | Cyclopentane Gas Sensor |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
MSR Germany n-Heptane Gas Sensor
Product Brochure
Response Time | 10 second |
Measuring Range | 0-100% LEL |
Expected Operating Life | 3-5 years |
Operating Temperature | -20-50 |
Operating Humidity | 95% |
Weight | 1.2 Kg |
Display Type | Digital,Analog |
Model Name/Number | n-Heptane Gas Sensor |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
MSR Germany IECEx, ATEX, SIL2 Toluene Gas Sensor
Product Brochure
Response Time | 10 second |
Measuring Range | 0-100% LEL |
Expected Operating Life | 3-5 years |
Operating Temperature | -20-50 |
Operating Humidity | 95% |
Brand | MSR Germany |
Display Type | Analog,Digital |
Weight | 1.2 Kg |
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
MSR Germany Nonane Gas Detector
Product Brochure
Display Type | Digital |
Model Name/Number | MC2-X-P3495-A-X-X |
Brand | MSR Germany |
Material | Polycarbonate Enclosure |
Color | Grey |
Sensor Type | Catalytic Pellistor |
Weight | 200gms |
Voltage | 24VDC |
Gas Type | Combustible Gas |
Usage/Application | Industrial |
Measurement Range | 0-100% LEL |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C9H20 Combustible gas.
Tiche MC2-X-P3495-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C9H20 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts.
MSR Germany Methyl Ethyl Ketone Gas Detector
Product Brochure
Storage Temperature | +5 DegreeC to +30 DegreeC |
Response Time | < 15 sec. (CH4) |
Measuring Range | 0-100% LEL |
Operating Temperature | -30 DegreeC to +60 DegreeC |
Signal Output | Analog 4-20mA |
Operating Humidity | 5-95 % RH not condensing |
I Deal In | New Only |
Color | Grey |
Usage/Application | Industrial |
Brand | MSR Germany |
Model Name/Number | MC2-X-P3458-A-X-X |
Measurement Range | 0-100% LEL |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C4H8O Combustible gas.
The MC2-X-P3458-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C4H8O sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
MSR Germany Isopropyl Alcohol Gas Detector
Product Brochure
Signal Output | Analog 4-20mA |
Sensor Type | Catalytic Pellistor |
Material | Polycarbonate Enclosure |
Brand | MSR Germany |
Color | Grey |
Mounting Type | Depending on Gas |
I Deal In | New Only |
Accuracy | 1% LEL |
Humidity Range | 5-95 % RH not condensing |
Display Type | Digital |
Power | 24VDC |
Weight | 200gms |
Model Name/Number | MC2-X-P3482-A-X-X |
Measurement Range | 0-100% LEL |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C3H8O Combustible gas.
The MC2-X-P3482-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C3H8O sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
MSR Germany Petrol Vapours Detector
Product Brochure
Minimum Order Quantity | 10 Piece |
Output Current | Analog 4-20mA |
Sensor Type | Catalytic Pellistor |
Material | Polycarbonate Enclosure |
Brand | MSR Germany |
Color | Grey |
Mounting Type | Depending on Gas |
Response Time | < 15 sec. (CH4) |
I Deal In | New Only |
Humidity | 5-95 % RH not condensing |
Power | 24VDC |
Weight | 200gms |
Display Type | Digital |
Gas Type | Combustible Gas |
Model Name/Number | MC2-X-P3460-A-X-X |
Usage/Application | Industrial |
Measurement Range | 0-100% LEL |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Petrol Vapours.
The MC2-X-P3496-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Petrol Vapours sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Ammonia Gas Detectors
Product Brochure
Minimum Order Quantity | 10 Piece |
Brand | MSR |
Color | Grey |
Resolution | 0.1 |
Sensor Type | Electrochemical sensor |
Gas Type | Ammonia |
Weight | 150 g |
Display Type | Analog,Digital |
Model Name/Number | MC2-X-E1125-XX-X |
Usage/Application | Industrial |
Measurement Range | 0-100, 0-300, 0-500, 0-1000 PPM |
Gard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Ammonia (NH3) Toxic gas.
The MC2-X-E1125-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical Ammonia (NH3) sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
Digital measurement value processing incl. temperature compensationData / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
High accuracy, selectivity, and reliability
Low zero point drift
Sensor life time: Refer the datasheet
SIL2 Compliant development process
Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
Reverse polarity protected, overload and short-circuit proof
Integrated heating down to -35C
Optional:Without housing
With housing Plastic: Type D, 94 x 65 x 57 mm
4-20 mA output signal
2-10 V output signal
With display for values and operation, 2x open collector for horn and warning lamp
Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe Gas Detectors and Alarm Systems
Msr Germany Methane Gas Detector
Product Brochure
Storage Temperature | +5 DegreeC to +30 DegreeC |
Response Time | < 15 sec. (CH4) |
Measuring Range | 0-100% LEL |
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | 5-95 % RH not condensing |
I Deal In | New Only |
Color | Grey |
Usage/Application | Industrial |
Sensor Type | Catalytic Pellistor |
Brand | MSR Germany |
Power | 24VDC |
Weight | 200gms |
Display Type | Digital |
Model Name/Number | MC2-X-P3400-A-X-X |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect Methane Combustible gas.
The MC2-X-P3400-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the CH4 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
MSR Germany Iso/n-Butane Gas Detector
Product Brochure
Storage Temperature | +5 DegreeC to +30 DegreeC |
Response Time | < 15 sec. (CH4) |
Measuring Range | 0-100% LEL |
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | 5-95 % RH not condensing |
Weight | 200gms |
Display Type | Digital |
Model Name/Number | MC2-X-P3460-A-X-X |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C4H10 Combustible gas.
The MC2-X-P3460-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C4H10 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Be sure, Be safe – Gas Detectors and Alarm Systems
MSR Germany Methanol Gas Detector
Product Brochure
Storage Temperature | +5 DegreeC to +30 DegreeC |
Response Time | < 15 sec. (CH4) |
Measuring Range | 0-100% LEL |
Operating Temperature | -30 DegreeC to +60 DegreeC |
Mounting Type | Depending on Gas Type |
Operating Humidity | 5-95 % RH not condensing |
I Deal In | New Only |
Color | Grey |
Usage/Application | Industrial |
Sensor Type | Catalytic Pellistor |
Brand | MSR Germany |
Power | 24VDC |
Weight | 200gms |
Display Type | Digital |
Model Name/Number | MC2-X-P3450-A-X-X |
Measurement Range | 0-100% LEL |
μGard2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect CH3OH Combustible gas.
The MC2-X-P3450-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the CH3OH module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
MSR Germany Toluene Gas Detector
Product Brochure
Storage Temperature | +5 DegreeC to +30 DegreeC |
Response Time | < 15 sec. (CH4) |
Measuring Range | 0-100% LEL |
Operating Temperature | -30 DegreeC to +60 DegreeC |
Operating Humidity | 5-95 % RH not condensing |
Usage/Application | Industrial |
Sensor Type | Catalytic Pellistor |
Operating Voltage | 24VDC |
Material | Polycarbonate Enclosure |
Brand | MSR Germany |
Color | Grey |
I Deal In | New Only |
Weight | 200gms |
Model Name/Number | MC2-X-P3490-A-X-X |
UGard 2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect C7H8 Combustible gas.
The MC2-X-P3490-A-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the C7H8 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
- Digital measurement value processing incl. temperature compensation
- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.