ALVI Automation India Private Limited
ALVI Automation India Private Limited
Kusum Vihar, Jaipur, Rajasthan
SEND SMS
SEND EMAIL

Gas Detector for Monitoring & Control Appication

Gas Alarm Gas Leak Monitoring Systems and Sensor are valuable for various industries like oil/gas, chemical, Manufacturing, petrochemical, pharmaceutical, building, mining, nuclear, steel, defense, power, water, wastewater, mining, cement, dairy, automobile etc.

Gas Alarm

Gas Alarm
  • Gas Alarm
Ask For Price

Product Details:

VoltageAC230V
Frequency50-60Hz
Power3W
TypeGas Alarm

Request
Callback
Yes! I am interested

Carbon Dioxide Sensor Transmitter 0- 5000 PPM

Carbon Dioxide Sensor Transmitter 0- 5000 PPM
  • Carbon Dioxide Sensor Transmitter 0- 5000 PPM
  • Plant
  • Carbon Dioxide Sensor Transmitter 0- 5000 PPM
  • Carbon Dioxide Sensor Transmitter 0- 5000 PPM
Get Best Quote
Approx. Price: Rs 8,000 / Unit

Product Details:

Measuring Range0-5000 ppm
Signal Output4-20mA, 0-10V DC
Operating Temperature-10 Degree C to 50 Degree C

MSR Electronic, Germany Carbon Dioxide (CO2) sensor transmitter includes digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air to detect carbon dioxide concentrations.


Features:

  • Technology: NDIR (Gold plated NDIR sensing cell)
  • Life expectancy: >15 years, normal operating environment
  • Protection housing: IP30, IP65, stainless steel, duct housing
  • Poison / over flood protection, Reverse polarity protected, overloadand short-circuit proof
  • Relay output, Integrated buzzer, LCD display, (optional)


Application:
  • Building ventilation and air-conditioning
  • Cold stores, ripening chambers, warehouse
  • Food processing, beverages
  • Agriculture, horticulture, incubators
  • Industrial application, combustion analysis etc .
Request
Callback


Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: Road / Air
  • Production Capacity: 100/ week
  • Delivery Time: EX Stock
Yes! I am interested
View PDF

Gas CO2 Temperature & Humidity Detection Monitoring Sensor

Gas CO2 Temperature & Humidity Detection Monitoring Sensor
  • Gas CO2 Temperature & Humidity Detection Monitoring Sensor
Ask For Price

Product Details:

Measuring Range0~2000ppm
Voltage220VAC
Power Consumption3.5 W
TypeDetection Monitoring Sensor

Real time carbon dioxide detection and monitoring Temperature and humidity detection and display Three-color backlit LCD Provide 1xon/off output to control a ventilator Wall mounting CE-approval

Features:
  • Design for real time monitoring room carbon dioxide level
  • NDIR infrared CO2 sensor inside with special
  • Self Calibration System. It makes the CO2 measurement more accurate and more reliable in use.
  • More than 10 years lifetime of CO2 sensor
  • Temperature and humidity monitoring only
  • Three-color (green/yellow/red) LCD backlit indicating ventilation optimal/moderate/poor based on the CO2 measurement
  • Backlit colour switches depending on CO2 reading
  • Manual on/off or auto operation
  • Includes 1xrelay output to control a ventilator
  • Easy touch button for operation
  • Optional RS–485 communication interface, 15 KV antistatic protection, individual IP address
  • 240VAC or 24VAC/VDC power option
  • EU standard and CE-approval

Application
New GAS-CO2-002-CDR monitor/alarm is used to monitoring room CO2 level, as well as room temperature and humidity. It provides one on/off output to control a ventilator with four CO2 levels presets. It has a 3 colour backlit display, which changes depending on the CO2 level. RS485 communication interface optional to connect with a PC or other control systems. Hotel, exhibition hall, hospital, shop, restaurant, air port, train station, theater and other public places House, villa, office, meeting room, classroom and other rooms All ventilation systems
Request
Callback
Yes! I am interested

Gas Alarm Systems MSR Ammonia NH3 Sensor

Gas Alarm Systems MSR Ammonia NH3 Sensor
  • Gas Alarm Systems MSR Ammonia NH3 Sensor
Ask For Price

Product Details:

DisplayDigital
TypeGas Alarm Systems
Voltage220V
UsageIndustrial

ALVI Automation India in association with Gas alarm systems, Australia are pleased to offer MSR Germany, Polygard Gas monitor for Ammonia, NH3.

Ammonia, NH3, is highly toxic gas and is also highly explosive at very high concentrations.

Gas Alarm India with ALVI Technologies Australia have MSR Gas Detector, Gas Analyzer, Gas Sensor, Gas Transmitter under MSR Polygard range to meet world critical safety standards for life and plant protection

Our product range includes MSR microgard, MA-0-11xx, MC2-E11xx, ADT-x3-34xx, ADT-x3-11xx, SPC-x3-11xx.
Request
Callback
Yes! I am interested

Gas Alarm Air Duct Probe Transmitter Device

Gas Alarm Air Duct Probe Transmitter Device
  • Gas Alarm Air Duct Probe Transmitter Device
Ask For Price

Product Details:

Measuring Range0-2000 ppm
Output Signal4-20mA
Frequency Range50-60Hz

Carbon Dioxide Duct Probe Transmitter series designed to be installed in HVAC return air ducts. 1 x analog outputs for CO2

Features :
  • Designed for air duct installation
  • Continuous monitoring
  • NDIR Infrared CO2 sensor
  • 15 year lifetime
  • 1 / 3, 2-10VDC or 4-20 mA analog outputs
  • Modbus RS485 comms interface
  • IP54 Housing
  • CE Approval
  • Optional Humidity & Temp detection
  • LCD display

Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard Series controllers the MGC/DGC as well as any other electronic control or automation system.
Request
Callback
Yes! I am interested

Gas Alarm Systems

Gas Alarm Systems
  • Gas Alarm Systems
Ask For Price

Product Details:

TypeGas Alarm System
Output Signal4-20mA
Working VoltageDC12V
Power1.5W

Specification:
Gas TypeMeasuring Range AvailableType Available
Hydrogen0-100% LELMA, ADT, MC2, SPC
Hydrogen Chloride0 – 20 / 200 ppmMA, ADT, MC2, SPC
Hydrogen Cyanide0-100 ppmMA, ADT, MC2, SPC
Hydrogen Fluoride0-10 ppmMA, ADT, MC2, SPC
Hydrogen Sulphide0 – 50 / 200 ppmMA, ADT, MC2, SPC
Iso butane0-100% LELMA, ADT, MC2, SPC
Iso Butyl Alcohol0-100% LELMA, ADT, MC2, SPC
Iso Pentane0-100% LELMA, ADT, MC2, SPC
Iso Propanol Alcohol0-100% LELMA, ADT, MC2, SPC
Iso propyl alcohol0-100% LELMA, ADT, MC2, SPC
LPG Liquefied Petrol Gas0-100% LELMA, ADT, MC2, SPC
Mercaptan (thiols) (-SH)0-10 ppmMA, ADT, MC2, SPC
Methane0-100% LEL
 
 
MA, ADT, MC2, SPC
Methanol0-100% LEL
 
 
MA, ADT, MC2, SPC
Methyl ethyl ketone0-100% LELMA, ADT, MC2, SPC
Natural Gas (CNG / PNG)0-100% LELMA, ADT, MC2, SPC
n-Butane
 
 
0-100% LELMA, ADT, MC2, SPC
n-Heptane0-100% LELMA, ADT, MC2, SPC
n-Hexane0-100% LELMA, ADT, MC2, SPC
Nitrogen Dioxide0-10 / 20 ppmMA, ADT, MC2, SPC
Request
Callback
Yes! I am interested

MSR Germany pH Meter Sensor

MSR Germany pH Meter Sensor
  • MSR Germany pH Meter Sensor
Ask For Price

Product Details:

Power SupplyAC220V+-22V, 50Hz
Accuracy+/-1% F.S.
Output Signal0-10mA/ 40-20mA
Temperature Consumption0~150 Degree

pH is a measure of the acidity/basicity of water. The control of pH is important during drinking water treatment, to maximize treatment effectiveness and efficiency, and in the distribution system, to control corrosion and reduce leaching from distribution system and plumbing components.

 

The Water which is introduced into out drinking water system must meet the most versatile requirements concerning hygiene and certain corrosion requirements to protect the water pipes. To identify potential treatment challenges and to evaluate the technologies ,pH is one of several general water quality variables that must be considered when selecting and configuring the treatment sequences for a given water source. To achieve this, one of the a broadly used procedure is the open aeration of raw water. The raw water can contain disturbing, corrosive carbon dioxide, which is driven off by aeration. Depending on the origin of water, also iron and manganese compounds are oxidized and then filtered.

 

During this process the raw water is sprayed through pumps and distributed over large surface packages in so-called trickling towers. To increase the efficiency, the aeration space can be blown with air from below in counter flow process.

 

When the raw waters have an excess of carbon dioxide and are not in lime/carbon dioxide equilibrium, the pH value of the raw water must be increased. The water is ventilated to saturate it with oxygen and reduce the solubility of Carbon dioxide, which is partially dissolved as carbonic acid when in equilibrium, is driven off.

 

This increases the pH value. The raw water typically has a pH of approximately 6.5 which shall be increased to pH + 7.5. To optimize the energy input of the pumps. The pH value is continuously measured after the aeration process. At each aeration tower the aeration Pumps are controlled via the pH Value.

 

The pH value is measured through a bypass line in the open outlet at the existing hydrostatic pressure. Depending on the number of measuring points, transmitters of the stratos series can be used or multichannel measurements using protos analyzers can be taken.

Request
Callback
Yes! I am interested

Gas Alarm System Gas Sensor Detector

Gas Alarm System Gas Sensor Detector
  • Gas Alarm System Gas Sensor Detector
Ask For Price

Product Details:

TypeSensor Detector Monitor
Power3W
Operating Temperature10 to 50 deg C
Gas TypeNatural Gas, Combustible Gas
Display TypeDigital, Analog
Detector FeaturesAdjustable Sensitivity
BrandMSR Germany

Specification:
Gas typeMeasuring RangeType Available
Nitrogen Trifluoride5-50 ppmMA, ADT, MC2, SPC
n-Octane0-100% LELMA, ADT, MC2, SPC
Nonane0-100% LELMA, ADT, MC2, SPC
n-Pentane0-100% LELMA, ADT, MC2, SPC
Oxygen0-25% / 30% / 100% VolMA, ADT, MC2, SPC
Ozone0-5 / 10/ 200 ppmMA, ADT, MC2, SPC
Petrol vapours0-100% LELMA, ADT, MC2, SPC
Phosphine0-5 ppmMA, ADT, MC2, SPC
Propane0-100% LELMA, ADT, MC2, SPC
Propyl alcohol0-100% LELMA, ADT, MC2, SPC
Propylene -propene0-100% LEL

MA, ADT, MC2, SPC
Silane0-50 ppmMA, ADT, MC2, SPC
Styrene0-100% LELMA, ADT, MC2, SPC
Sulphur Hexafluoride0-1000 ppmMA, ADT, MC2, SPC
Sulphur Dioxide0 - 10 / 20 ppmMA, ADT, MC2, SPC
Tetrahydrothiophene

0-14 PPMMA, ADT, MC2, SPC
Toluene0-100% LELMA, ADT, MC2, SPC
Trimethyl Amine0-100PPMMA, ADT, MC2, SPC
Trimethyl benzene0-100%MA, ADT, MC2, SPC
Volatile organic compound (VOC)0-4000% LELMA, ADT, MC2, SPC
Xylene0-100% LELMA, ADT, MC2, SPC
Request
Callback


Additional Information:

  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
Yes! I am interested

MSR Germany Gas Alarm Sensors Monitoring Systems

MSR Germany Gas Alarm Sensors Monitoring Systems
  • MSR Germany Gas Alarm Sensors Monitoring Systems
Ask For Price

Product Details:

Voltage100-240V AC
PowerLess than 2W
Working Temperature-20 Degree C~+50 Degree C

Specification:
ModelMakeTypeApplication / ApprovalsMeasuring RangeContact MediaKey Features
901 ExBeckSwitchHazardous area zone 0, zone 1, zone 2, ATEX certified0-20 mbarLiquids, gases - also aggressiveAdjustable switch knob, for pressure, vacuum, differential pressure; media temperature: -20° to +85° cel
930BeckSwitchNon-hazardous area, safe0-4000 PaAir, non-aggressive gasesadjustable switch knob, for pressure, vacuum, differential pressure
930 ExBeckSwitchHazardous area zone 0, zone 1, zone 2, ATEX certified0-4000 PaAir, non-aggressive gasesadjustable switch knob, for pressure, vacuum, differential pressure
984mBeckTransmitterNon hazardous area, safe0-100 Pa to 0-250 kPaAir, non-aggressive gasesTo measure differential pressure, over pressure and vacuum pressure; dual pressure range jumper selectable; 0-10V / 4-20mA output, with/without display
DA03FischerGaugeNon hazardous area, safe0 - 40 mbar to 0 -25 bar (or as per requirement)Air, water, liquids, aggressive media, chemicals, process industriesWith / without Adjustable limit contacts, with / without Proximity type non-contact limit detector; with / without Pointer position transducer with electrical signal output
Request
Callback
Yes! I am interested

Gas Analyzers

Gas Analyzers
  • Gas Analyzers
Ask For Price

Product Details:

DisplayDigital
Working Voltage90-240VAC
Humidity Range10% ~ 95%
TypeGas Alarm

Analytical industry terminology frequently separates biogas and landfill applications into two different categories even though the gas itself is similar. Landfill sites have diversified waste input streams which seem to have an averaging effect on the gas composition from site to site.

The gas can be quite aggressive and corrosive. But from a gas analyzer perspective, landfill applications are generally predictable and consistent enough to allow standard analytical equipment to be specified.

Biogas applications may have gas that is produced from uniform feedstocks utilizing specific plant designs. For example, a palm oil facility will likely have only agricultural waste originating from a palm oil plantation. This means that the produced gas may be more characterized. It is therefore wise to obtain an analysis of gas composition and conditions before specifying permanent analytical equipment. Biogas applications also frequently have multiple sample points or other requirements that need to be addressed.

Gas Production

Biogas results from the metabolic activity of microorganisms on organic matter. Landfill gas is a type of biogas that originates from the decomposition of organic waste in a landfill. Biogas production is not isolated to landfill waste only. Any organic waste may be decomposed in the absence of oxygen to produce biogas. Agricultural waste and the effluent from wastewater treatment plants are frequently utilized as sources of biogas.

This process, called anaerobic digestion, produces primarily methane and carbon dioxide. Several other gases are also produced such as nitrogen, oxygen, hydrogen sulfide and others. Anaerobic digestion is a multi-stage process comprised of different microbes and chemical reactions.

Landfill and Biogas Gas Measurement

If the produced gas is being burned for power or for carbon credits, it is important to know in advance what the specific makeup of the gas is. It is also important to know this information on a permanent continuous basis. This is why an analyzer system is frequently required somewhere between the output of the gas supply line and the input of the receiving process.

The analyzer will provide a percent by volume reading of the methane (CH4) and carbon dioxide (CO2) levels. The oxygen (O2) readings on the analyzer may be useful in determining if there is an inbound air leak in the collection system. An analyzer equipped with carbon monoxide (CO) analysis may be useful for detecting a subsurface fire. Based on these results, adjustments or repairs can be made to restore safe conditions and optimize the heating value of the gas produced.
Request
Callback
Yes! I am interested

Gas Alarm System

Gas Alarm System
  • Gas Alarm System
Get Best Quote
Approx. Price: Rs 10,000 / Unit

Product Details:

TypeGas Alarm System
Voltage220V
Temperature-10 ~ 50 Degree C
Average Consumption Less than 1.5W

Gas Alarm System Msr Sensor Analyzer, Detector List

Alvi Automation Introduce MSR Germany Sensor:-
Ethane0-100% LELSPC-34xx,, XT-A1-34xxI
Ethyl Acetate0-100% LELSPC-34xx,
Ethyl Alcohol0-100% LELSPC-34xx,, XT-A1-34xxI
Ethyl Mercaptan0-200 ppm, 0-100% LELSPC-34xx
Ethylene0- 10 / 500 / 1000 / 2000 ppm, 0-100% LELSPC-34xx,SPC-TOX,,, XT-A1-34xxI
Ethylene Oxide0-20 ppmSPC-TOX
Fluorine0- 1 / 5 ppmSPC-TOX
Formaldehyde0-10 ppmSPC-TOX
Freon / Refrigerants0-2000 ppm

Hydrazine0-1 ppmSPC-TOX
Request
Callback
Yes! I am interested

Gas Detector

Gas Detector
  • Gas Detector
Get Best Quote
Approx. Price: Rs 1 Lakh / Unit

Product Details:

Working Voltage15~30VDC
Output Signal4-20mA
Reponse TimeLess than equal 30s
Display TypeDigital

Specification:
Gas TypeMeasuring RangeAvailableType Available
Acetic Acid0-100% LELMA, ADT, MC2, SPC
Acetone0-100% LELMA, ADT, MC2, SPC
Acetylene0-100% LELMA, ADT, MC2, SPC
Air QualityCO2 + VOCMA, ADT, MC2, SPC
Ammonia (NH3)0-300 / 1000 / 35,000 ppm, 0-100% LELMA, ADT, MC2, SPC
Benzene0-100% LELMA, ADT, MC2, SPC
carbon dichloride oxide – Phosgene0-1 ppmMA, ADT, MC2, SPC
Carbon Dioxide0-2000 / 5000 / 20,000 / 50, 000 ppm, 0-20% / 100% VolMA, ADT, MC2, SPC
Carbon Monoxide0-300 / 2000 ppm, 0-2% / 5% / 20% / 100% VolMA, ADT, MC2, SPC
Chlorine0-5 / 10 / 20 ppmMA, ADT, MC2, SPC
Chlorine Dioxide0-1 ppmMA, ADT, MC2, SPC
Cyclopentane0-100% LELMA, ADT, MC2, SPC
Dinitrogen oxide (Laughing gas)0-2000 ppmMA, ADT, MC2, SPC
Ethane0-100% LELMA, ADT, MC2, SPC
Ethyl Acetate0-100% LELMA, ADT, MC2, SPC
Ethyl Alcohol0-100% LELMA, ADT, MC2, SPC
Ethyl Mercaptan-200 ppm, 0-100% LELMA, ADT, MC2, SPC
Ethylene0- 10 / 500 / 1000 / 2000 ppm, 0-100% LELMA, ADT, MC2, SPC
Ethylene Oxide0-20 ppmMA, ADT, MC2, SPC
Fluorine0- 1 / 5ppmMA, ADT, MC2, SPC
Request
Callback
Yes! I am interested

MSR Ethyl Acetate Sensor

MSR Ethyl Acetate Sensor
  • MSR Ethyl Acetate Sensor
Ask For Price

Product Details:

Output Signal4-20mA
UsageIndustrial
Power Frequency50Hz
TypeMagnetic Sensor

Ethyl Acetate Sensor, Analyzer, Transmitter For Industrial, Oil, Chemical Application, Ethyl Acetate Sensor, Transmitter, Analyzer For Flammability Monitoring. Alvi Automation Gas Alarm India Offer Ethyl Acetate Sensor Transmitter / Detector/ Analyser From Msr Electronic, Germany With Following Features:
  • Measuring Range: 0-100% Lel (Lower Limit), 0-100% Vol (Analysis)
  • Technology: Pellistor / Catalytic Bead (Flammability Monitoring), Infra-red
  • Enclosure: Ip44, Ip54, Ip65
  • Certificate: Ul 61010, Ul 2075, Atex Eexd, Atex Eexn, Ce
  • Mounting: Wall Mountable, Duct Mountable
  • Installation Area: Safe Area, Hazardous Area, Explosion-proof

Application Areas:
Gas Bank, Bottling Plant, Booster Station, Gas Store, Pharmaceutical, Cylinder Store, Gems Processing, Heat Processing, Furnace, Engine Room, Testing Rooms, Automobile, Defence, Warship, Anniling Plant, Chemical Plants, Oil & Gas, Fire Safety, Domestic Gas Pipeline, Kitchen, Refinery, Food Processing, Cement, Bearing, Machine Industry, Swimming Pool, Combustion Area, Bakery, Commerical, Hotels, Mines, Confined Space, Gasifer, Stockyard, Oil Wells, Biogas Plant, Landfill, Boiler Plant, Thermal Power Plants Etc

Features:
  • Reverse Polarity Protected
  • Poisoning Protected
  • Low Flashing Temperature For Longer Sensor
  • Modular Architecture
  • Manual Calibration
  • Expected Life > 3 Years, > 15 Years
  • Low Response Time

Gas Type Available:
Combustible Gas Detector, Confined Space Gas Detector, Gas Detection System, Gas Detectors, Gas Analyzers, Exhaust Gas Analysers, Fermentation, Fermentator, Landfill, Stack Gas Analyser, Catalytic Gas Sensor, Combustible Gas Sensor, Gas Sensors, Methane Detector, Gas Train, Combustion Analyzer, Biogas Generation Plant, Biogas Generator, Biogas Power Generation Plant, Biomass Gasifier.
Request
Callback
Yes! I am interested

Gas Leak Detector In Hazardous Zone

Gas Leak Detector In Hazardous Zone
  • Gas Leak Detector In Hazardous Zone
Ask For Price

Product Details:

TypeGas Leak Detector
MaterialStainless Steel
Gas TypeCombustible Gas
BrandMSR
Display TypeDigital, Analog
Power SourcePlug-In
Detector FeaturesAdjustable Sensitivity

Gas Alarm Systems Australia in association with Gas alarm systems India are pleased to introduce MSR Germany, Polygard Gas Detector for Butane, C4H10, LPG. Butane, C4H10, LPG is highly explosive, Combustible gas Gas Alarm India with Gas Alarm Systems Australia have MSR Gas Detector, Gas Analyzer, Gas Sensor, Gas Transmitter under MSR Polygard range to meet world critical safety standards for life and plant protection. Our product range includes MSR microgard, MA-0-11xx, MC2-E11xx, ADT-x3-34xx, ADT-x3-11xx, SPC-x3-11xx, Polyzeta 2 for hazardous zone 1, zone 2 areas. it has IEC EX, ATEX certification with SIL 2. All products and systems are manufactured in Germany , hence quality and reliability are assured.
Request
Callback


Additional Information:

  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),Other,Cheque
  • Port of Dispatch: AIR or road
  • Production Capacity: 50
  • Delivery Time: 4 week
Yes! I am interested
View PDF
X

Explore more products

Looking for “Gas Detector for Monitoring & Control Appication”?


Reach Us
Alak Jha (Director)
Plot No. 350, Ram Gali No. 8, Jagatpura
Kusum Vihar, Jaipur- 302017, Rajasthan, India



Call Us

Share Us

F GT L


Send E-mailSend SMS