ALVI Automation India Private Limited
ALVI Automation India Private Limited
Kusum Vihar, Jaipur, Rajasthan
SEND SMS
SEND EMAIL

Flammable, Combustible Gas Leak Detector

We bring state-of-the-art technology & control methods that add value to customers through a combination of multiple high-end technologies for complete solutions. We have the competence and capability to integrate all products, systems and services. Save time and money with an integrated GasAlarm solution today!

Hydrogen Gas Leak Detector

Hydrogen Gas Leak Detector
  • Hydrogen Gas Leak Detector
  • Plant
  • Hydrogen Gas Leak Detector
  • Hydrogen Gas Leak Detector
  • Hydrogen Gas Leak Detector
  • Hydrogen Gas Leak Detector
Get Best Quote
Approx. Price: Rs 30,000 / UnitGet Latest Price

Product Details:

Minimum Order Quantity1 Unit
GreyGrey
ModelMC2
Measurement Range0-100% LEL
Display TypeDigital, Analog
Gas TypeH2
MaterialPoly carbonate
Model NumberMC2

Product Description:

Battery rooms or battery charging bays or battery charging stacks are being widely used in Data Center, UPS Systems, Renewable Energy Sources like Solar Plants, Wind farms, Submarines, Naval Vessels and Underground Bunkers etc.

Features:
  • MA-2-3440-F-M and MC2-X-2-3440-A-X
  • MSR, Germany micro-gard Hydrogen sensor transmitter, Catalytic pellistor, 0-100% LEL H2 in IP65 enclosure with features:
  • Continuous monitoring
  • Low zero point drift
  • Poisoning stable
  • Long life sensor
  • Easy maintenance / calibration
  • Reverse polarity protected
  • Overload protected
  • IP 44 protected enclosure
  • Short circuit reverse polarity protected
  • Plug-in sensor PCB for easy service and replacement

These batteries when being charged generate, liberate highly explosive Hydrogen (H2) gas. The LEL(Lower Explosive Limit) of Hydrogen (H2) is 4 % Vol. and the UEL (Upper Explosive Limit) is 77 % Vol. Hydrogen (H2) is lighter than air and travels towards ceiling in an enclosed battery room.

The potential risk of this Hydrogen (H2) generation liberation in battery rooms are:
  • The potential for creating a highly explosive atmosphere which can create explosions in the battery rooms due to electrical sparks, electrical short-circuits electrical earth leakage and high surge capacitive discharge.
  • Oxygen depletion atmosphere in an enclosed battery room thereby causing breathing safety hazard for working humans.

Solutions:
  • To design engineer install a continuous Hydrogen (H2) detection and monitoring system and to control the ventilation fans to remove the built-up Hydrogen (H2) gas.
  • ALVI Automation India in association with Gas Alarm Systems, Sydney Australia, and MSR, Germany can design, engineer and supply Hydrogen (H2) sensor transmitter along with gas monitoring control panels for controlling the ventilation fans in the battery rooms to dissipate the explosive atmosphere. We have a range of sensor transmitter with 4-20 mA analog output, stand-alone single point gas controllers, multi-channel digital Modbus centralized gas control systems.
  • MSR, Germany product range includes ATEX, IEC-Ex, SIL2 Hazardous area certified for zone-1 and zone-2 hazardous atmospheres.
  • All from MSR, Germany hence quality and reliability are assured. All systems supplied by ALVI Automation India will be supported, calibrated, maintained, serviced as per Global standards.
Request
Callback


Additional Information:

  • Item Code: MC2Series
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Port of Dispatch: Road/Air
  • Production Capacity: 100
  • Delivery Time: Per Day
Yes! I am interested
View PDF

H2 Gas Leak Detector

H2 Gas Leak Detector
  • H2 Gas Leak Detector
  • Plant
  • H2 Gas Leak Detector
  • H2 Gas Leak Detector
  • H2 Gas Leak Detector
  • H2 Gas Leak Detector
Ask For Price
Product Price :Get Latest Price

Product Details:

Gas TypeNatural Gas, Combustible Gas, Hydrogen Gas
BrandMSR
Display TypeAnalog
Cross SensitivityVery less
BuzzerYes inbuilt
External Power RequiredYes
Weight150 gm

Product Description:

Battery rooms or battery charging bays or battery charging stacks are being widely used in Data Center, UPS Systems, Renewable Energy Sources like Solar Plants, Wind farms, Submarines, Naval Vessels and Underground Bunkers etc.

Features:
  • MA-2-3440-F-M and MC2-X-2-3440-A-X
  • MSR, Germany micro-gard Hydrogen sensor transmitter, Catalytic pellistor, 0-100% LEL H2 in IP65 enclosure with features:
  • Continuous monitoring
  • Low zero point drift
  • Poisoning stable
  • Long life sensor
  • Easy maintenance/calibration
  • Reverse polarity protected
  • Overload protected
  • IP 65 protected enclosure
  • Short circuit reverse polarity protected
  • Plug-in sensor PCB for easy service and replacement

These batteries when being charged generate, liberate highly explosive Hydrogen (H2) gas. The LEL(Lower Explosive Limit) of Hydrogen (H2) is 4 % Vol. and the UEL (Upper Explosive Limit) is 77 % Vol. Hydrogen (H2) is lighter than air and travels towards the ceiling in an enclosed battery room.

The potential risk of this Hydrogen (H2) generation liberation in battery rooms are:
  • Potential for creating a highly explosive atmosphere which can create explosions in the battery rooms due to electrical sparks, electrical short-circuits electrical earth leakage and high surge capacitive discharge.
  • Oxygen depletion atmosphere in an enclosed battery room thereby causing breathing safety hazard for working humans.

Solutions:
  • To design engineer install a continuous Hydrogen (H2) detection and monitoring system and to control the ventilation fans to remove the built-up Hydrogen (H2) gas.
  • ALVI Automation India in association with Gas Alarm Systems, Sydney Australia and MSR, Germany can design, engineer and supply Hydrogen (H2) sensor transmitter along with gas monitoring control panels for controlling the ventilation fans in the battery rooms to dissipate the explosive atmosphere. We have a range of sensor transmitter with 4-20 mA analog output, stand-alone single point gas controllers, multi-channel digital Modbus centralized gas control systems.
  • MSR, Germany product range includes ATEX, IEC-Ex, SIL2 Hazardous area certified for zone-1 and zone-2 hazardous atmospheres.
  • All from MSR, Germany hence quality and reliability are assured. All systems supplied by ALVI Automation India will be supported, calibrated, maintained, serviced as per Global standards.
For more details please mail us at info@alviautomation.com 
Request
Callback


Additional Information:

  • Item Code: MC2-A-P3440-A-1
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),Other
  • Port of Dispatch: By Air
  • Delivery Time: Ex-Stock
Yes! I am interested
View PDF

LPG Gas Leak Detector

LPG Gas Leak Detector
  • LPG Gas Leak Detector
  • Plant
  • LPG Gas Leak Detector
  • LPG Gas Leak Detector
  • LPG Gas Leak Detector
  • LPG Gas Leak Detector
  • LPG Gas Leak Detector
  • LPG Gas Leak Detector
  • LPG Gas Leak Detector
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity1 Piece
UsageIndustrial
TypeGas Leak Detection
Gas TypeNatural Gas, Combustible Gas
Power SourcePlug-In
Detector FeaturesAdjustable Sensitivity
Display TypeDigital, Analog
BrandMSR Germany
Response Time10 sec
Operating VoltageAC240V or DC24V

Gas Alarm India pleased to offer LPG sensor transmitter / Leakage detector/ Analyser in association with ALVI Technologies- Australia & MSR Germany with following features:

  • Measuring range: 0-100% LEL (lower explosive limit), 0-100% Vol (analysis)
  • Technology: Pellistor / catalytic bead (flammability monitoring), Infra-red
  • Output: 4-20mA, 2-10V, RS485 Modbus, Lon, BACnet
  • Enclosure: IP44, IP54, IP65
  • Certificate: UL 61010, UL 2075, ATEX EExd, IEC-Ex, CE
  • Mounting: wall mountable, duct mountable
  • Installation area: safe area, hazardous area, explosion-proof

Application areas: Kitchen , gas bank, bottling plant, booster station, gas

store, pharmaceutical, cylinder store, gems processing, heat processing, furnace, engine room, testing rooms, automobile, defence, warship, annealing plant, chemical plants, oil & gas, fire safety, domestic gas pipeline, kitchen, refinery, food processing, cement, bearing, machine industry, swimming pool, combustion area, bakery, commercial, hotels, mines, confined space, gasifier, stockyard, oil wells, biogas plant, landfill, boiler plant, thermal power plants etc.


Features:

  • Reverse polarity protected
  • Poisoning protected
  • Low flashing temperature for longer sensor
  • Modular architecture
  • Manual calibration
  • Expected life: 3 years-15 years
  • Low response time
  • Conformity to
    o EN 50271
    o EN 61010-1
    o ANSI/UL 61010 1
    o CAN/CSA-C22.2 No. 61010-1

Gas type available: combustible gas detector, confined space gas detector, gas detection system, gas detectors, gas analyzers, exhaust gas analysers, biogas analyzers, stack gas analyser, catalytic gas sensor, combustible gas sensor, gas sensors, hydrogen gas sensor, methane detector, LPG bottling plants, LPG burners, LPG cylinder plant, LPG fuel tank, LPG gas leakage sensor, gas train, LPG gas tanker, LPG station, LPG vaporizer, natural gas alarm, natural gas plants, combustion analyzer, biogas generation plant, biogas generator, biogas power generation plant, biomass gasifier, propane vaporizers.

For more details please mail us at info@alviautomation.com 

Request
Callback


Additional Information:

  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),D/P
Yes! I am interested
View PDF

Hydrogen Gas Detector for Battery Room

Hydrogen Gas Detector for Battery Room
  • Hydrogen Gas Detector for Battery Room
  • Plant
  • Hydrogen Gas Detector for Battery Room
  • Hydrogen Gas Detector for Battery Room
  • Hydrogen Gas Detector for Battery Room
  • Hydrogen Gas Detector for Battery Room
  • Hydrogen Gas Detector for Battery Room
  • Hydrogen Gas Detector for Battery Room
  • Hydrogen Gas Detector for Battery Room
  • Hydrogen Gas Detector for Battery Room
  • Hydrogen Gas Detector for Battery Room
  • Hydrogen Gas Detector for Battery Room
  • Hydrogen Gas Detector for Battery Room
  • Hydrogen Gas Detector for Battery Room
Ask For Price
Product Price :Get Latest Price

Product Details:

Battery TypePower supply
Driven TypePLC or Analog Output
IndicatorsYes
Gas TypeNatural Gas, Combustible Gas, Hydrogen Gas Detector
Indicator ColorRed
TechniqueCatalytic Pellistor
Model NumberMC2-X-P3440-A-0
Temperature (Deg. Celsius)0-50
MaterialPolycarbonate
Power SourcePlug-In
Detector FeaturesAdjustable Sensitivity
ModelMC2
Measurement Range0-100% LEL
ColorGrey
Alarm TypeFlash hooter
BrandMSR Germany
Dimension (mm)137*67
Power (A)24Vdc
Display TypeAnalog
Alarm SystemYes

Product Description:

Battery rooms or battery charging bays or battery charging stacks are being widely used in Data Center, UPS Systems, Renewable Energy Sources like Solar Plants, Wind farms, Submarines, Naval Vessels and Underground Bunkers etc.

Features:
  • MA-2-3440-F-M and MC2-X-2-3440-A-X
  • MSR, Germany micro-gard Hydrogen sensor transmitter, Catalytic pellistor, 0-100% LEL H2 in IP 65 enclosure with features:
  • Continuous monitoring
  • Low zero point drift
  • Poisoning stable
  • Long life sensor
  • Easy maintenance/calibration
  • Reverse polarity protected
  • Overload protected
  • IP 65 protected enclosure
  • Short circuit reverse polarity protected
  • Plug-in sensor PCB for easy service and replacement

These batteries when being charged generate, liberate highly explosive Hydrogen (H2) gas. The LEL(Lower Explosive Limit) of Hydrogen (H2) is 4 % Vol. and the UEL (Upper Explosive Limit) is 77 % Vol. Hydrogen (H2) is lighter than air and travels towards ceiling in an enclosed battery room.

The potential risk of this Hydrogen (H2) generation liberation in battery rooms are:
  • Potential of creating highly explosive atmosphere which can create explosions in the battery rooms due to electrical sparks, electrical short-circuits, electrical earth leakage and high surge capacitive discharge.
  • Oxygen depletion atmosphere in an enclosed battery rooms there by causing breathing safety hazard for working humans.

Solutions:
  • To design engineer install a continuous Hydrogen (H2) detection and monitoring system and to control the ventilation fans to remove the built-up Hydrogen (H2) gas.
  • ALVI Automation India in association with Gas Alarm Systems, Sydney Australia and MSR, Germany can design, engineer and supply Hydrogen (H2) sensor transmitter along with gas monitoring control panels for controlling the ventilation fans in the battery rooms to dissipate the explosive atmosphere. We have range of sensor transmitter with 4-20 mA analog output, stand alone single point gas controllers, multi channel digital Modbus centralised gas control systems.
  • MSR, Germany product range includes ATEX, IEC-Ex, SIL2 Hazardous area certified for zone-1 and zone-2 hazardous atmospheres.
  • All from MSR, Germany hence quality and reliability are assured. All systems supplied by ALVI Automation India will be supported, calibrated, maintained, serviced as per Global standards.
Request
Callback


Additional Information:

  • Item Code: MC2-D-P3440-A-0
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),Other
  • Port of Dispatch: By Air
  • Production Capacity: 1000
  • Delivery Time: within 1 week
Yes! I am interested
View PDF

Flameproof Gas Leak Detector

Flameproof Gas Leak Detector
  • Flameproof Gas Leak Detector
  • Flameproof Gas Leak Detector
  • Flameproof Gas Leak Detector
  • Flameproof Gas Leak Detector
  • Flameproof Gas Leak Detector
  • Flameproof Gas Leak Detector
  • Flameproof Gas Leak Detector
Ask For Price
Product Price :Get Latest Price

Product Details:

TypeGas Leak Detector
MaterialStainless Steel
Gas TypeCombustible Gas
BrandMSR
Display TypeDigital, Analog
Power SourcePlug-In
Detector FeaturesAdjustable Sensitivity

Gas Alarm Systems Australia in association with Gas alarm systems India are pleased to introduce MSR Germany, Polygard Gas Detector for Butane, C4H10, LPG. Butane, C4H10, LPG is highly explosive, Combustible gas Gas Alarm India with Gas Alarm Systems Australia have MSR Gas Detector, Gas Analyzer, Gas Sensor, Gas Transmitter under MSR Polygard range to meet world critical safety standards for life and plant protection. Our product range includes MSR micro guard, MA-0-11xx, MC2-E11xx, ADT-x3-34xx, ADT-x3-11xx, SPC-x3-11xx, Polyzeta 2 for hazardous zone 1, zone 2 areas. it has IEC EX, ATEX certification with SIL 2. All products and systems are manufactured in Germany, hence quality and reliability are assured.


For more details please mail us at info@alviautomation.com
Request
Callback


Additional Information:

  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),Cheque
  • Port of Dispatch: AIR or road
  • Production Capacity: 50
  • Delivery Time: 4 week
Yes! I am interested
View PDF
X

Explore more products



Reach Us
Alak Jha (Director)
Plot No. 350, Ram Gali No. 8, Jagatpura
Kusum Vihar, Jaipur- 302017, Rajasthan, India



Call Us

Share Us

F GT L


Send E-mailSend SMS